3.  Place the o-ring over the exposed end of the glass thimble and seat the o-ring firmly against the 

thread, as shown above. 

4.  When the o-ring is seated, install the knurled nut onto the chamber to seal the o-ring against the 

sealing nut. NOTE: Firmly hand tightening is sufficient to seal these chambers without the use of 

tools – DO NOT APPLY THREAD TAPE OR SEALANT GLUE TO THE END THREADS. 

Caution: Overtightening the end nuts may cause the glassware to crack.

 

5.  You can look through the open end of the nut to see if the o-ring is seated correctly. There will likely 

be a slight gap between the end edge of the thimble and the recessed stop-end of the knurled nut - 

this is normal in most cases (for the 2K & 4K Systems). On the larger GT7-8K & GT7-9K systems, 

the spring holds the quartz under tension, so there may not be a gap once firmly tightened. 

From this point, the water supply should be turned on to pressurise the chamber and identify if there are 

any leaks from the plumbing connections or from the thimble. If leaking occurs from the thimble, it is 

possible that it may only be a slow beading leak which must to be rectified before installing the lamp. 
For vertical installations, it is extremely important that there are no slow leaks, as over time, these will fill up 

the thimble with water and cause a short in the lamp, which can result in injury or damage to the lamp & 

ballast. This is not covered under warranty. 
If any water is present on the thimble or chamber from the installation process, it will need to be thoroughly 

dried before continuing with the installation.  

II. Ballast Operation 

GT7-8K-PS

 – The 10W – 40W ballast is straightforward for operation. It features a lamp status & failure 

indicator light along with an audible alarm should there be a fault. The ballast will automatically reset when 

turned on/off. 

GT7-16K-PS

 - In order to guarantee user safety, this ballast features complete control and protection 

functions which are caused by; 

1.  UV Lamp exceeding life cycle (365 Days). 

2.  UV Lamp Failure. 

3.  Working beyond rated voltage and load. 

This ballast is designed to work with germicidal UV lamps. Do not mistake the input/output wire to avoid 

ballast failure. 

  Ensure the voltage is within the specification of the ballast. 

  Match the UV lamp with the power output of the ballast. 

  Ensure the connections (plugs) are fitted correctly – the earth wire must be affixed securely. 

Working Condition:

 Green LED light of ballast ON, No Red LED, Digital Display indicating # of Days 

Fault:

 Red LED on / Flashing, Audible alarm 

Working Timer Function: 

The First timer indicates number of operating days from 0 to 9999, the Second 

timer indicates UV lamp working life which is a countdown from 365 days to 0. The UV lamp working life is 

set by default but you can switch between these indicators by pressing and holding the “SELECT” button 

for 2 Seconds (repeat this to return to Default). 

UV Lamp Replacement Alarm:

 Once the UV lamp working day timer reaches 0, the digital display will 

show “A3”. The Red LED light will flash and there will be an audible alarm to remind you to change to a 

new lamp. 

Ballast Reset:

 When the lamp has been changed, press and hold the “SELECT” button for 10 seconds 

until the display shows “RSET” – Continue holding for a further 5 seconds until the display shows “0365” 

and you will hear an audible beep. Release the button and the timer is successfully reset. 

III. Installing the UV Lamp 

When, and only when the chamber and thimble are deemed to be water-tight and free of leaks, can the 

lamp be installed. Handle the lamp only by the plastic end caps, and support it by both ends. 

Содержание GT7-16K

Страница 1: ...ements 3 VI What is Ultraviolet Sanitation 3 VII Example Applications 3 Installation Introduction 4 I Site Preparation 4 II Mounting 4 III Installing Connections 4 IV Thermal Relief Valve 4 V Filter P...

Страница 2: ...must be followed closely to prevent serious personal injury Ensure eye protection is worn when servicing and installing this unit to protect from harmful UV C Radiation This radiation can be harmful...

Страница 3: ...ounding plumbing must be earthed to prevent electrolysis which will cause corrosion VI What is Ultraviolet Sanitation Ultraviolet sanitation works by breaking down the cell wall of a micro organism al...

Страница 4: ...to install a TRV to limit the temperature When installing a TRV note the below requirements The TRV must be installed on the Outlet of the UV System which should be the open end The TRV tube must be a...

Страница 5: ...ure indicator light along with an audible alarm should there be a fault The ballast will automatically reset when turned on off GT7 16K PS In order to guarantee user safety this ballast features compl...

Страница 6: ...as waterproof 6 Connect the earth wire to the lug on the bottom of the UV chamber as shown above 7 Plug the ballast into a certified single socket surge protector then into a 240V 10A GPO 8 Turn on t...

Страница 7: ...PS 10W 40W AU Certified RCM Ballast to Suit 4 Pin Lamps GT7 16K PS 33W 120W AU Certified RCM Ballast to Suit 4 Pin Lamps Mounting Clamps GT11 8G 1 PC Plastic Mounting Clamp Suitable for U Sink Instal...

Страница 8: ...check for Water ingress from either rain or leaks or any signs of moisture or condensation in around the electricals Due to the elevated temperature of the lamp high humidity may cause condensate to f...

Страница 9: ...ff check connections and turn back on to see if it fixes the alarm 2 The ballast could have a problem with the lamp failure protection and may require replacement Turn the system off check connections...

Страница 10: ...buyer is responsible for keeping record and proof of installation in the form of an invoice and or receipt UV Systems must be connected to a surge protector Directly before being connected to 240V so...

Страница 11: ...of invoice Power Supply 1 Year GT7 8K GT7 9K GT7 16K Stainless Steel UV Reactor Chamber 10 Years Quartz Thimble 1 Year Pro Rata from date of invoice UV Lamp 1 Year Pro Rata from date of invoice Power...

Отзывы: