background image

 

GT1-39RODI Aquarium 

RO System 

Contents 

WARNING:

 ...................................................................................................................................................................... 2 

I. Before You Begin

 .................................................................................................................................................... 2 

II. Important Note:

 ....................................................................................................................................................... 2 

Reverse Osmosis Filtration

 ........................................................................................................................................... 2 

I. Overview

 ................................................................................................................................................................... 2 

II. Feed Water Conditions

 ......................................................................................................................................... 2 

Installing Inlet Fitting

 ...................................................................................................................................................... 2 

I. Kitchen Diverter Valve (Not Supplied)

 ................................................................................................................. 2 

II. ¾” Garden Tap Adaptor (Supplied as Standard)

 .............................................................................................. 3 

III. Washing Machine Block Adaptor (Supplied as Standard)

 ............................................................................. 3 

IV. Connecting Tubing Using Compression Fittings

 ............................................................................................. 3 

System Installation/Start-Up

 ......................................................................................................................................... 4 

I. Pre-Flushing

 ............................................................................................................................................................. 4 

II. Tubing Connections

 ............................................................................................................................................... 4 

III. Initial Start-Up

 ........................................................................................................................................................ 4 

IV. Using the System

 ................................................................................................................................................. 5 

V. After Use & Storage

 .............................................................................................................................................. 5 

VI. Long Periods of no use

 ....................................................................................................................................... 5 

TDS Monitor

 .................................................................................................................................................................... 5 

I. What is TDS

 ............................................................................................................................................................. 5 

II. Installation

 ............................................................................................................................................................... 5 

III. Usage

 ..................................................................................................................................................................... 6 

IV. Calibration

 ............................................................................................................................................................. 6 

V. Changing Batteries

 ................................................................................................................................................ 6 

Maintenance

 .................................................................................................................................................................... 7 

I. Sanitation

 ................................................................................................................................................................. 7 

II. Replacement Parts

 ................................................................................................................................................ 7 

III. Replacement Filters

 ............................................................................................................................................. 7 

IV. Testing Filters

 ....................................................................................................................................................... 7 

Troubleshooting

 .............................................................................................................................................................. 7 

Replacement Filters & Parts

 ....................................................................................................................................... 11 

 

 

Содержание GT1-39RODI

Страница 1: ...k Adaptor Supplied as Standard 3 IV Connecting Tubing Using Compression Fittings 3 System Installation Start Up 4 I Pre Flushing 4 II Tubing Connections 4 III Initial Start Up 4 IV Using the System 5...

Страница 2: ...rger molecules from the water carrying them to waste Reverse Osmosis membranes do not have a litre Capacity for filter replacements due to the variables that can make the filter life vary significantl...

Страница 3: ...the Kitchen Diverter Valve but this time you firstly turn off the cold water to your washing machine lay a towel down for water leakage Using either your hands or a pair of gripping tools slowly unscr...

Страница 4: ...ure everything looks sound there are no kinks damaged fittings or tubing that is not plugged in Connect the inlet filter to the inlet side of the membrane screw cap end You should have 2 lengths of tu...

Страница 5: ...the desired level 5 If the TDS level is still too high open the flush valve for another 30 seconds then close and check VI After Use Storage The system can then be stored away in a cabinet if you have...

Страница 6: ...ution that is correct for your needs The calibration solution should be NaCl HM Digital s 342 ppm NaCl is recommended 2 Disconnect both T fittings from their tubes Do not remove the sensor from the T...

Страница 7: ...DS reading exceeds your desired level The membrane itself has a largely varying life time It may last anywhere between 1 and 4 years depending on usage water quality and age This can also be monitored...

Страница 8: ...side if it is damaged it may need replacing this is a common size washer and can be purchased from most hardware plumbing stores 2 If the diverter valve is loose or you can easily swivel the fitting w...

Страница 9: ...specified amount 3 If you have good pressure and average water quality it is possible there is a small blockage somewhere in the system Try to follow the water flow along the system disconnecting 1 t...

Страница 10: ...there is a strong foul smell or organic taste to the water it is possible that there is some form of contamination Contact us straight away so we can rectify or diagnose the problem if there is one p...

Страница 11: ...lter 6 Months GT4 1C Clear Refillable Cannister Post Filter 12 24 Months GT5 12S MB 115 Tulsion De Ionising Resin as Required GT13 37 ALP 100GPD Reverse Osmosis Membrane 1 4 years TDS Testing Required...

Страница 12: ...A plumber is not legally required for this type of installation unless a new tap or water outlet is required The system is compliant to WaterMark AS NZS 3497 and therefore is compliant with permanent...

Страница 13: ...s extended warranty covers the below parts of the system GT8 31 Reverse Osmosis Housing GT8 0S Twin O ring White Housing GT1 39 Models Only GT8 38S Twin O ring Clear Housing GT1 39 Models Only The fol...

Отзывы: