check the newest stored data. Then short press       button and       button to check the 

previous stored data. Short press        button to exit the data-saving interface.

6. OPM - Reference

       button is used to set the reference value or switch the absolute or relative value. 

Press for 2 seconds or longer, "REF" sign will display on the screen after flashing 3 times, 

the instrument will use the current measurements to overwrite the original setting 

value and set it as a new reference value. Meanwhile LCD will display set REF value 

(dBm) and dB value. Each wavelength can set their own reference value.

Short press        button can convert between absolute and relative value. The absolute 

value on the screen will display the measuring absolute value (dBm/uW), the relative 

value on the screen will display the "REF", the setting REF value (dBm) and the difference 

between actual measured value and reference value (dB).

7. OLS - Laser On/Off 

When the instrument is powered on, short press        button to turn on/off OLS function. 

If OLS is off, it will display "OFF" in the LCD. If OLS is on, it will display the current 

wavelength of OLS.

8. OLS - Select Wavelength

When turning on OLS, press        button to select the output wavelength you need. If 

using other OPM to test the OLS power, then the OPM should select the same 

wavelength as OLS has.

9. OLS - Modulation Output

Short press        button, you can load a modulation in the current output laser, and 

display modulation (270Hz, 1kHz, 2kHz). Connecting with an optical power meter with 

frequency identification function, the OPM can identify the laser's current load 

modulation, and load a same frequency.

LASER

ON/OFF

RECORD

-2s SAVE

REF

-2s SEF

REF

-2s SEF

MOD

-2s ID

OPM

λ

OLS

λ

Содержание FHOM-103

Страница 1: ...F MOD 2s ID MENU 2s ON OFF Set OPM λ OLS λ 2s ESC OPTICAL MULTI METER CAUTION LASER RADIATION DO NOT STARE INTO BEAM MAXIMUM OUTPUT 30mW WAVELENGTH 640 660 nm CLASS III LASER PRODUCT LASER RADIATION CAUTION DO NOT STARE INTO BEAM MAXIMUM OUTPUT 1mW WAVELENGTH 800 1700 nm CLASS II LASER PRODUCT ...

Страница 2: ...data network telecommunication network and cable television The figures below display the product images of the two optical multimeters FHOM 201 FHOM 103 Optical Multi Meter Zs PERM λ λ VFL Save Laser ON MOD REF Unit LASER ON OFF RECORD 2s SAVE REF 2s SEF MOD 2s ID MENU 2s ON OFF Set OPM λ OLS λ 2s ESC OPTICAL MULTI METER CAUTION LASER RADIATION DO NOT STARE INTO BEAM MAXIMUM OUTPUT 30mW WAVELENGT...

Страница 3: ...FHOM 103 USB Cable x1 ST Adapter x1 SC Adapter x1 FC Adapter x1 AC Adapter x1 Installing Install FC fiber cable Inserting FC Cables ...

Страница 4: ...1 Install ST connector Inserting ST Cables 2 Install ST fiber cable ...

Страница 5: ...2 Install SC fiber cable 1 Install SC connector Inserting SC Cables ...

Страница 6: ...gth Down Button LASER ON OFF RECORD 2s SAVE REF 2s SEF MOD 2s ID MENU OPM λ OLS λ LASER ON OFF RECORD 2s SAVE REF 2s SEF MOD 2s ID MENU 2s ON OFF Set OPM λ OLS λ 2s ESC OPTICAL MULTI METER CAUTION LASER RADIATION DO NOT STARE INTO BEAM MAXIMUM OUTPUT 30mW WAVELENGTH 640 660 nm CLASS III LASER PRODUCT LASER RADIATION CAUTION DO NOT STARE INTO BEAM MAXIMUM OUTPUT 1mW WAVELENGTH 800 1700 nm CLASS II ...

Страница 7: ...s to exit Menu setting 4 OPM Select Wavelength According to the project s demand we need to measure optical signals of different wavelengths Then we need to select a corresponding wavelength to measure the optical power If the measured wavelength is different from the wavelength we selected on OPM it will lead to the measuring values meaningless After turning on press button to switch OPM waveleng...

Страница 8: ... the relative value on the screen will display the REF the setting REF value dBm and the difference between actual measured value and reference value dB 7 OLS Laser On Off When the instrument is powered on short press button to turn on off OLS function If OLS is off it will display OFF in the LCD If OLS is on it will display the current wavelength of OLS 8 OLS Select Wavelength When turning on OLS...

Страница 9: ...Data Save Recall Button OPM Unit Shift Button OPM Reference Check Set Button Laser Source On Off Button Laser Source Wavelength Shift Button Laser Source Modulation Button λ λ VFL Save Laser ON MOD REF Unit Optical Multi Meter Zs PERM λ λ VFL Save Laser ON MOD REF Unit Function Introductions FHOM 103 ...

Страница 10: ... 1310nm 1490nm 1550nm 1625nm 4 OPM WAVE ID optional Long press button to turn on the WAVE ID and display at the same time Long press again to exit the WAVE ID 5 OPM Select Unit Press button for shifting the unit from dBm nW uW mW after pressing button it shifts to dB After power off the current unit will be saved nW uW mW 1mW 1000uW 1uW 1000nW dBm dBm 10 log mW dB dB dBm REF 6 OPM Reference Press ...

Страница 11: ... DC adaptor for charging And do not charge the non rechargeable batteries or the device will be destroyed and also lose the guarantee Sufficient power Less power Long press button to save the current value 8 OLS On Off Press button to turn on off the laser source output 9 OLS Select Wavelength WAVE ID Short press button to shift the wavelength Long press 2s the button to turn on WAVE ID function t...

Страница 12: ... html https www fs com service help_center html https www fs com contact_us html Maintenance 1 The interface is sensitive please carefully plug in and pull out connectors 2 Keep using one type of optical adapter to avoid excess loss from different connectors 3 Please use dust proof cap for protection to avoid being scratched or contaminated when not in operation 4 It is important to keep all optic...

Отзывы: