CHAPTER 2:  INSTALLATION INSTRUCTIONS 

 

 

2.1 General

 

 

Proper installation is essential for the safe, efficient, trouble-free operation of this appliance.   

 

Qualified, licensed, and/or authorized installation or service personnel, as defined in Section 
1.6 of this manual, should perform all installation and service on Frymaster equipment.  

 

Failure to use qualified, licensed, and/or authorized installation or service personnel (as 
defined in Section 1.6 of this manual) to install or otherwise service this equipment will void 
the Frymaster warranty and may result in damage to the equipment or injury to personnel. 

 

Where conflicts exist between instructions and information in this manual and local or 
national codes or regulations, installation and operation shall comply with the codes or 
regulations in force in the country in which the equipment is installed.

 

 

Service may be obtained by contacting your local Factory Authorized Service Center

.

 

 

NOTICE 

All fryers shipped without factory supplied cords and plug assemblies must be 
hardwired using flexible conduit to the terminal block located on the rear of the fryer.  
These fryers should be wired to NEC specifications.  Hardwired units must include 
installation of restraint devices. 

 

 DANGER 

Adequate means must be provided to limit the movement of this appliance without 
depending on or transmitting stress to the electrical conduit.  A restraint kit is 
provided with the fryer.  If the restraint kit is missing contact your local Frymaster 
Factory Authorized Service Center (FASC) for part number 826-0900. 

 

NOTICE 

If this equipment is wired directly into the electrical power supply, a means for 
disconnection from the supply having a contact separation of at least 3-mm in all 
poles must be incorporated in the fixed wiring. 

 

NOTICE 

This equipment must be positioned so that the plug is accessible unless other 
means for disconnection from the power supply (e.g., a circuit breaker) is provided. 

 

NOTICE 

If this appliance is permanently connected to fixed wiring, it must be connected by 
means of copper wires having a temperature rating of not less than 167°F (75°C). 

 

NOTICE 

If the electrical power supply cord is damaged, it must be replaced by a Frymaster 
Dean Factory Authorized Service Center technician or a similarly qualified person in 
order to avoid a hazard. 

Содержание YFPRE1817E

Страница 1: ...l Food Equipment Service Association recommends using CFESA Certified Technicians 24 Hour Service Hotline 1 800 551 8633 JULY 09 www frymaster com E mail service frymaster com 8196383 YFPRE1817E YFPRE...

Страница 2: ...STOMERS This equipment is to be installed in compliance with the basic plumbing code of the Building Officials and Code Administrators International Inc BOCA and the Food Service Sanitation Manual of...

Страница 3: ...fry baskets or other utensils on the fryer s joiner strip The strip is present to seal the joint between the fry vessels Banging fry baskets on the strip to dislodge shortening will distort the strip...

Страница 4: ...rements 2 1 2 2 Power Requirements 2 3 2 3 Positioning the Fryer Station 2 3 CHAPTER 3 Operating Instructions 3 1 Setup and Shutdown Procedures 3 2 3 2 Controller 3 3 CHAPTER 4 Filtration Instructions...

Страница 5: ...ion about actions or conditions that may cause or result in injury to personnel and which may cause damage to your system and or cause your system to malfunction Fryers in this series are equipped wit...

Страница 6: ...ns QUALIFIED AND OR AUTHORIZED OPERATING PERSONNEL Qualified authorized operating personnel are those who have carefully read the information in this manual and have familiarized themselves with the e...

Страница 7: ...cked notify the freight company or carrier immediately and file a concealed damage claim This should be done within 15 days of date of delivery Be sure to retain container for inspection 1 7 Service I...

Страница 8: ...g flexible conduit to the terminal block located on the rear of the fryer These fryers should be wired to NEC specifications Hardwired units must include installation of restraint devices DANGER Adequ...

Страница 9: ...r s will automatically shut down If this occurs turn the power switch OFF Do not attempt to start the fryer s until power is restored This appliance must be kept free and clear of combustible material...

Страница 10: ...legs the bottom of the legs can be screwed out up to one inch for leveling Legs should also be adjusted so that the fryer s are at the proper height in the frying station For fryers equipped with cas...

Страница 11: ...ting to move it to avoid oil spills falls and severe burns This fryer may tip and cause personal injury if not secured in a stationary position 2 Close fryer drain valve s and fill frypot with water t...

Страница 12: ...TION YFPRE1817E SHOWN NOTE The appearance of your fryer may differ slightly from that shown depending upon the configuration and date of manufacture Tilt Housing Basket Hanger Lift Rod Top Cap Bezel C...

Страница 13: ...k of solid shortening on top of the heating elements When using solid shortening always pre melt the shortening before adding it to the frypot If the shortening is not pre melted it must be packed dow...

Страница 14: ...s the first time the fryer is being used after installation refer to the frypot Boil Out Procedure on Page 5 2 Refer to the separate Frymaster Wingstreet Controller User s Manual furnished with your f...

Страница 15: ...3 4...

Страница 16: ...edures WARNING When operating the filtration system never leave the filter unattended The action of the oil moving through the hose lines could jolt a flexible return hose where applicable out of the...

Страница 17: ...t in filter systems 4 2 Filtration Preparation On initial installation and before each use remove all loose parts from the filter wash the filter pan and all accessories in hot soapy water and dry tho...

Страница 18: ...the filter pad The notch goes around the pick up tube 4 Place the crumb screen in the filter pan Allow the crumb screen to rest on the top edges of the hold down ring 5 Place filter pan cover onto the...

Страница 19: ...ning and technical procedures and may not conform to on site management operational procedures 4 3 1 General Overview The filter pump is turned on only after the oil is brought to operating temperatur...

Страница 20: ...rge debris from oil prior to filtering Note Always wear oil resistant insulated gloves and or protective gear when working with hot oil 4 4 Operating the Filter DANGER Draining and filtering of cookin...

Страница 21: ...h the cleanout rod or other objects Damage to the ball inside will result in leaks and will void all applicable warranties 4 4 1 Pan Preparation See Section 4 2 1 Assembling the Filter and Section 4 2...

Страница 22: ...l to circulate for approximately 30 minutes process known as polishing to remove suspended particles 9 After the filter cycle is complete close the drain valve push the blue handle to the left until i...

Страница 23: ...see DANGER statement below DANGER The crumb tray in fryers equipped with a filter system must be emptied into a fireproof container at the end of frying operations each day Some food particles can sp...

Страница 24: ...d to the concentration of cleaner and the length of time the cleaner remains on the food contact surfaces 5 1 1 Clean Inside and Outside of the Fryer Cabinet Daily Clean inside the fryer cabinet with...

Страница 25: ...Inspect the elements for signs of extensive dry firing Verify that the tilt mechanism is working properly when lifting and lowering elements and that the element wires are not binding and or chafing...

Страница 26: ...filtration system integrity as follows Verify that filter pan cover is present and properly installed With the filter pan empty place each oil return handle one at a time in the ON position Verify tha...

Страница 27: ...y corrective action involves taking steps to ensure that it doesn t happen again If a controller malfunctions because of a poor connection check all other connections too If a fuse continues to blow f...

Страница 28: ...upply system including the transformer and interface board fail power will not be supplied to the controller and it will not function Call FASC A Drain valve is open A A drain safety switch prevents t...

Страница 29: ...r cord is not plugged in or circuit breaker is tripped A Verify that the power cord is fully plugged in If so verify that circuit breaker is not tripped B Pump motor has overheated causing the thermal...

Страница 30: ...le wire to remove the blockage If the blockage cannot be removed call FASC A Improperly installed filter pan components A If using filter paper or pad configuration verify that filter screen is in bot...

Страница 31: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 32: ...ster L L C 8700 Line Avenue Shreveport Louisiana 71106 TEL 1 318 865 1711 FAX Parts 1 318 688 2200 Tech Support 1 318 219 7135 819 6383 PRINTED IN THE UNITED STATES SERVICE HOTLINE 1 800 551 8633 JULY...

Отзывы: