2.2 Power 

Requirements 

 
 

Three (3) Phase Requirements 

MODEL VOLTAGE 

WIRE 

SERVICE

MINIMUM WIRE 

SIZE 

AWG         (mm) 

AMPS 

(per leg) 

YFPRE1817E 208 

3  6 (4.11) 

48 

 240 

(4.11) 

41 

 480 

(4.11) 

21 

 220/380 

(4.11) 

26 

 240/415 

(4.11) 

24 

 230/400 

(4.11) 

25 

 

 
 

2.3 

After Fryers Are Positioned At the Frying Station 

 

 

DANGER

 

No structural material on the fryer should be altered or removed to accommodate 
placement of the fryer under a hood.  Questions?  Call the Frymaster Dean Service 
Hotline at 1-800-551-8633. 

 

 

1.

 

Once the fryer has been positioned at the frying station, use a carpenter’s level placed across the 
top of the frypot to verify that the unit is level, both side-to-side and front-to-back. 

 

To level fryers equipped with legs, the bottom of the legs can be screwed out up to one inch for 
leveling.  Legs should also be adjusted so that the fryer(s) are at the proper height in the frying station. 

 

For fryers equipped with casters, there are no built-in leveling devices. The floor where the 
fryers are installed must be level. 

 

When the fryer is leveled in its final position, install the restraints provided with the unit to limit 
its movement so that it does not depend on or transmit stress to the electrical conduit or 
connection. Install the restraints in accordance with the provided instructions (see illustration 
below). If the restraints are disconnected for service or other reasons, they must be reconnected 
before the fryer is used. 

 

 

 

 

NOTE

:

  If you need to relocate a fryer installed with legs, remove all weight from each leg 

before moving.  If a leg becomes damaged, contact your service agent for immediate repair or 
replacement. 

 

Содержание YFPRE1817E

Страница 1: ...l Food Equipment Service Association recommends using CFESA Certified Technicians 24 Hour Service Hotline 1 800 551 8633 JULY 09 www frymaster com E mail service frymaster com 8196383 YFPRE1817E YFPRE...

Страница 2: ...STOMERS This equipment is to be installed in compliance with the basic plumbing code of the Building Officials and Code Administrators International Inc BOCA and the Food Service Sanitation Manual of...

Страница 3: ...fry baskets or other utensils on the fryer s joiner strip The strip is present to seal the joint between the fry vessels Banging fry baskets on the strip to dislodge shortening will distort the strip...

Страница 4: ...rements 2 1 2 2 Power Requirements 2 3 2 3 Positioning the Fryer Station 2 3 CHAPTER 3 Operating Instructions 3 1 Setup and Shutdown Procedures 3 2 3 2 Controller 3 3 CHAPTER 4 Filtration Instructions...

Страница 5: ...ion about actions or conditions that may cause or result in injury to personnel and which may cause damage to your system and or cause your system to malfunction Fryers in this series are equipped wit...

Страница 6: ...ns QUALIFIED AND OR AUTHORIZED OPERATING PERSONNEL Qualified authorized operating personnel are those who have carefully read the information in this manual and have familiarized themselves with the e...

Страница 7: ...cked notify the freight company or carrier immediately and file a concealed damage claim This should be done within 15 days of date of delivery Be sure to retain container for inspection 1 7 Service I...

Страница 8: ...g flexible conduit to the terminal block located on the rear of the fryer These fryers should be wired to NEC specifications Hardwired units must include installation of restraint devices DANGER Adequ...

Страница 9: ...r s will automatically shut down If this occurs turn the power switch OFF Do not attempt to start the fryer s until power is restored This appliance must be kept free and clear of combustible material...

Страница 10: ...legs the bottom of the legs can be screwed out up to one inch for leveling Legs should also be adjusted so that the fryer s are at the proper height in the frying station For fryers equipped with cas...

Страница 11: ...ting to move it to avoid oil spills falls and severe burns This fryer may tip and cause personal injury if not secured in a stationary position 2 Close fryer drain valve s and fill frypot with water t...

Страница 12: ...TION YFPRE1817E SHOWN NOTE The appearance of your fryer may differ slightly from that shown depending upon the configuration and date of manufacture Tilt Housing Basket Hanger Lift Rod Top Cap Bezel C...

Страница 13: ...k of solid shortening on top of the heating elements When using solid shortening always pre melt the shortening before adding it to the frypot If the shortening is not pre melted it must be packed dow...

Страница 14: ...s the first time the fryer is being used after installation refer to the frypot Boil Out Procedure on Page 5 2 Refer to the separate Frymaster Wingstreet Controller User s Manual furnished with your f...

Страница 15: ...3 4...

Страница 16: ...edures WARNING When operating the filtration system never leave the filter unattended The action of the oil moving through the hose lines could jolt a flexible return hose where applicable out of the...

Страница 17: ...t in filter systems 4 2 Filtration Preparation On initial installation and before each use remove all loose parts from the filter wash the filter pan and all accessories in hot soapy water and dry tho...

Страница 18: ...the filter pad The notch goes around the pick up tube 4 Place the crumb screen in the filter pan Allow the crumb screen to rest on the top edges of the hold down ring 5 Place filter pan cover onto the...

Страница 19: ...ning and technical procedures and may not conform to on site management operational procedures 4 3 1 General Overview The filter pump is turned on only after the oil is brought to operating temperatur...

Страница 20: ...rge debris from oil prior to filtering Note Always wear oil resistant insulated gloves and or protective gear when working with hot oil 4 4 Operating the Filter DANGER Draining and filtering of cookin...

Страница 21: ...h the cleanout rod or other objects Damage to the ball inside will result in leaks and will void all applicable warranties 4 4 1 Pan Preparation See Section 4 2 1 Assembling the Filter and Section 4 2...

Страница 22: ...l to circulate for approximately 30 minutes process known as polishing to remove suspended particles 9 After the filter cycle is complete close the drain valve push the blue handle to the left until i...

Страница 23: ...see DANGER statement below DANGER The crumb tray in fryers equipped with a filter system must be emptied into a fireproof container at the end of frying operations each day Some food particles can sp...

Страница 24: ...d to the concentration of cleaner and the length of time the cleaner remains on the food contact surfaces 5 1 1 Clean Inside and Outside of the Fryer Cabinet Daily Clean inside the fryer cabinet with...

Страница 25: ...Inspect the elements for signs of extensive dry firing Verify that the tilt mechanism is working properly when lifting and lowering elements and that the element wires are not binding and or chafing...

Страница 26: ...filtration system integrity as follows Verify that filter pan cover is present and properly installed With the filter pan empty place each oil return handle one at a time in the ON position Verify tha...

Страница 27: ...y corrective action involves taking steps to ensure that it doesn t happen again If a controller malfunctions because of a poor connection check all other connections too If a fuse continues to blow f...

Страница 28: ...upply system including the transformer and interface board fail power will not be supplied to the controller and it will not function Call FASC A Drain valve is open A A drain safety switch prevents t...

Страница 29: ...r cord is not plugged in or circuit breaker is tripped A Verify that the power cord is fully plugged in If so verify that circuit breaker is not tripped B Pump motor has overheated causing the thermal...

Страница 30: ...le wire to remove the blockage If the blockage cannot be removed call FASC A Improperly installed filter pan components A If using filter paper or pad configuration verify that filter screen is in bot...