YFG255 SERIES GAS RETHERMALIZERS
CHAPTER 1: SERVICE PROCEDURES
1-20
1.7.1 General Troubleshooting (cont.)
PROBLEM
PROBABLE CAUSES
CORRECTIVE ACTION
No burner flame.
A.
Pilot does not stay lit.
A.
Flame sensor possibly out of
alignment. Realign flame sensor.
Check flame sensor for loose wires.
B.
Pilot stays lit, and the flame sensor is
working, but burners fail to light.
B.
Inspect gas valve and replace if
defective.
C.
Gas valve is known to be good, but
there is not 24 VAC at the gas valve
terminals.
C.
Inspect temperature probe sensor
(while still in cookpot) for damage.
Replace if bent, dented or cracked.
Inspect leads for fraying, burning,
breaks and/or kinks. If found, remove
and replace temperature probe.
D.
Continuity from ignition module
block to gas valve is not "0".
D.
Inspect wiring for breaks or shorts and
repair if necessary.
1.8 Probe resistance Chart
Probe Resistance Chart
For use with rethermalizers using the Control Products Controller.
F
°
OHMS
C
°
50 1059 16
68 1070 18
77 1080 21
86 1091 24
104 1101
27
122 1112
29
140 1122
32
158 1133
35
176 1143
38
194 1154
41
212 1164
43