When installing Pasta Magic cookers in the 

UNITED STATES

, the installation must conform to the 

latest edition of the Nation Fuel Gas Code, ANSI Z223.1.  In addition, installation must comply with 
all local codes.  In 

CANADA

, installation must conform to Standard CAN/CGA-B149.1 or 

CAN/CGA-B149.2, 

Installation Codes for Gas Burning Appliances and Equipment

.  In addition, 

installation must comply with all local codes.  In 

AUSTRALIA

, this appliance must be installed by 

an authorized person in accordance with these instructions, local gas and electrical regulations, and 
the requirements of AA601, 

Installation Requirements for Gas Burning Appliances

.   

 
For countries not specifically listed above, installation shall comply with the national and local 
codes or regulations in force in the country in which the appliance is being installed. 
 

FCC COMPLIANCE 
 

The user is cautioned that any changes or modifications to Frymaster controllers not expressly 
approved by the party responsible for compliance could void the user’s authority to operate the 
equipment. 
 
Frymaster controllers have been tested and found to comply with the limits for a Class A digital 
device, pursuant to Part 15 of the FCC rules.  While these devices are verified as Class A devices, 
they have been shown to meet the Class B limits.  These limits are designed to provide reasonable 
protection against harmful interference when the equipment is operated in a commercial 
environment.  This equipment generates, uses, and can radiate radio frequency energy and, if not 
installed and used in accordance with the instruction manual, may cause harmful interference to 
radio communications.  Operation of the equipment in residential areas is likely to cause harmful 
interference in which case the user will be required to correct the interference at his own expense.  If 
necessary, the user should consult the dealer or an experience radio and television technician for 
additional suggestions.  The user may find the booklet “How to Identify and Resolve Radio-TV 
Interference Problems” helpful.  It is prepared by the Federal Communications Commission and is 
available form the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004-000-
00345-4. 

2.2 

Caster or Leg Installation 

Depending upon the specific configuration ordered your cooker may have been shipped without 
installed casters or legs.  If casters or legs are installed, you may skip this section and proceed to 
Section 2.3, 

Pre-Connection Preparations

 

If your cooker requires the installation of casters or legs, install them in accordance 
with the instructions included in your accessory package.   
 
 
 
 
 
 

Содержание Pasta Magic

Страница 1: ...ds using CFESA Certified Technicians 24 Hour Service Hotline 1 800 551 8633 MARCH 2014 8197126 Pasta Magic Gas Water Cooker Installation and Operation Manual CAUTION READ THE INSTRUCTIONS BEFORE USING...

Страница 2: ...cial applications for example in kitchens of restaurants canteens hospitals and in commercial enterprises such as bakeries butcheries etc but not for continuous mass production of food DANGER Improper...

Страница 3: ...from the local gas company or gas supplier DANGER Improper installation adjustment maintenance or service and unauthorized alterations or modifications can cause property damage injury or death Read...

Страница 4: ...ion to Gas Line 2 5 2 5 Converting to another Gas Type 2 7 CHAPTER 3 Operating Instructions 3 1 Finding Your Way Around the Pasta Cooker 3 1 3 2 Basic Functions 3 2 3 3 Operating Instructions 3 2 3 3...

Страница 5: ...zed Servicers FAS s is located on the Frymaster website at www frymaster com If you do not have access to this list contact the Frymaster Service Depart ment at 1 800 551 8633 or 1 318 865 1711 When o...

Страница 6: ...u will also find information boxes like the one below containing valuable information regarding the safe operation of the unit The following is an example Standard for Incoming Gas Pressures Gas Minim...

Страница 7: ...allation or service personnel as defined in Section 1 5 1 5 Definitions QUALIFIED INSTALLATION PERSONNEL Qualified installation personnel are individuals firms corporations and or companies which eith...

Страница 8: ...nspect for and record all visible loss or damage and ensure that this information is noted on the freight bill or express receipt and is signed by the person making the delivery 3 Concealed loss or da...

Страница 9: ...operation shall comply with the codes or regulations in force in the country in which the equipment is installed Upon arrival inspect the cooker carefully for visible or concealed damage See Shipping...

Страница 10: ...this appliance directly over a drain opening ELECTRICAL GROUNDING REQUIREMENTS All electrically operated appliances must be grounded in accordance with all applicable national and local codes A wirin...

Страница 11: ...devices are verified as Class A devices they have been shown to meet the Class B limits These limits are designed to provide reasonable protection against harmful interference when the equipment is op...

Страница 12: ...ng them so that the cooker is level and at the proper height in the exhaust hood NOTE There are no built in leveling devices on cookers equipped with casters The floor where the cooker is to be instal...

Страница 13: ...for the type of gas being used Standard for Incoming Gas Pressures Gas Minimum Maximum Natural 6 0 WC 1 62 kPa 16 19 mbar 14 WC 3 48 kPa 34 87 mbar Propane 11 WC 2 74 kPa 27 37 mbar 14 WC 3 48 kPa 34...

Страница 14: ...gas supply to the cooker and check all piping fittings and gas connections for leaks A soap solution should be used for this purpose DANGER Never use matches candles or any other ignition source to ch...

Страница 15: ...g Label 802 2144 Orifice 810 0403 2 required Ignitor Kit 826 0981 2 required Regulator 807 1847 1 required Conversion Rating Label 802 2144 Gas Conversion Instructions 1 Change the orifices 2 Change t...

Страница 16: ...ERATION MANUAL CHAPTER 3 OPERATING INSTRUCTIONS 3 1 Finding Your Way Around the Pasta Cooker Trouble light Cook pot Drain Overflow Low water float switch Thermostat Power Switch Power LED Boil Simmer...

Страница 17: ...E Do not use deliming solution to clean these units Use of deliming solution will damage all stainless steel parts To skim add enough water after cooking to overflow into the drain for about 10 second...

Страница 18: ...wait 60 seconds then repeat this step If the trouble light illuminates after four 4 minutes ensure that the gas valve is ON Cycle power and check for ignition 7 After the burners have been lit continu...

Страница 19: ...ld water and 1 cup of detergent 2 Place the unit into operation see Sections 3 3 1 and 3 3 2 3 Ensure the boil simmer switch is set to simmer and allow the solution to simmer for at least 1 hour 4 Aft...

Страница 20: ...ions that the equipment and accessories are not ready for safe operation Clean Cabinet Inside and Out Clean inside the cabinet with a dry clean cloth Wipe all accessible metal surfaces and components...

Страница 21: ...ensure it is clear 5 Reinstall the tube and bend it so that the opening is pointing downward 4 3 Cleaning and Adjusting the Combustion Air Blower 1 Unplug the cooker Mark and disconnect the four wires...

Страница 22: ...rdance with the procedure described in Chapter 3 Section 3 3 6 After the burners have been lit for at least 90 seconds observe the flames through the burner viewing ports The air gas mixture is proper...

Страница 23: ...Pressure Tap Plug 3 Insert the fitting for a gas pressure measuring device into the pressure tap hole 4 Place the gas valve in the ON position 5 Place the power switch in the ON position When the bur...

Страница 24: ...This is accomplished as follows 1 Place the power switch in the OFF position 2 Disconnect the sensing wire from one of the burner ignitors and connect it to the positive lead of the meter Connect the...

Страница 25: ...istance Before calling a servicer or the Frymaster HOTLINE 1 800 551 8633 Verify that electrical cords are plugged in and that circuit breakers are on Verify that water supply valves are open and that...

Страница 26: ...ition Wait 60 seconds and turn the power to the ON posi tion Wait at least 4 minutes B Stuck water level float switch If the float switch does not indi cate sufficient water in the cook pot it will no...

Страница 27: ...ted i e burners are lit A Failed thermostat A Call FAS WATER BOILS IN SIMMER MODE A Thermostat out of adjustment A Adjust thermostat in accord ance with procedure in Chapter 4 A Failed thermostat B Ca...

Страница 28: ...Shipping Address 8700 Line Avenue Shreveport Louisiana 71106 TEL 1 318 865 1711 Tech Support 1 318 219 7135 PRINTED IN THE UNITED STATES SERVICE HOTLINE 1 800 551 8633 Price 8 00 819 7126 MARCH 2014...