HEATED PASS THROUGH

INSTALLATION, OPERATION, SERVICE, AND PARTS

3

5.

Maintenance

Daily

1.

 

Remove all product and turn the unit off.

2.

 

Allow the unit to cool.

3.

 

Use a wet sanitized cloth to clean the heated surfaces of the unit. Use a nylon pot brush on hard
to remove stains or food items.

Monthly

Remove the filter screen and clean it with a wet sanitized cloth.  Dry the screen thoroughly before
reinstalling it in the unit.

6.

Service Procedures

6.1 

Adjusting the Temperature

A.

 

Disconnect the unit from the electrical power source.  

This is imperative.  Line voltage

is accessable on the controller board with the unit connected to the power source.

B.

 

A potentiometer regulates the heat produced by the air heater.  It is mounted on the
HPT’s controller board and is accessible through a slot in the left side of the cowl
assembly (see Figure 1 below).  

NOTE:

  The filter screen must first be removed.

Figure 1:  The potentiometer is accessible through the vent in the cowl

assembly indicated by the arrow.

C.

 

Use a long, narrow-blade screwdriver to turn the potentiometer clockwise to increase
the temperature; turn it counterclockwise to lower the temperature.

Figure 2:  The potentiometer, indicated by the arrow, is adjusted using
a narrow-blade screwdriver.

D.

 

Reconnect the HPT to the power source and check temperature.

Содержание Heated Pass Through none

Страница 1: ...rcial Food Equipment Service Association recommends using CFESA Certified Technicians Price 6 00 8195931 24 Hour Service Hotline 1 800 551 8633 819 5931 April 2003 Heated Pass Through Installation Ope...

Страница 2: ...____________________________________________ ______________________________________________________________________________ ____________________________________________________________________________...

Страница 3: ...3 Place product in the HPT in accordance with the restaurant s established procedures THIS APPLIANCE IS EQUIPPED WITH A GROUNDING PLUG FOR YOUR PROTECTION AGAINST SHOCK HAZARD AND MUST BE PLUGGED INT...

Страница 4: ...voltage is accessable on the controller board with the unit connected to the power source B A potentiometer regulates the heat produced by the air heater It is mounted on the HPT s controller board a...

Страница 5: ...side of the unit Grasp the old leads at the opposite end and gently pull them through the unit NOTE It is easier to pull one lead through at a time If the leads become disconnected while pulling them...

Страница 6: ...an the surfaces thoroughly and apply new gaskets R Slip the slotted brackets on the front section of the air tower assembly up and under the nuts on the tower mounting screws Push inward and down to e...

Страница 7: ...sket over the one already in place and reseat the front section O Once the front section is properly positioned and seated tighten the nuts on the mounting studs to pull it flush against the back of t...

Страница 8: ...HEATED PASS THROUGH INSTALLATION OPERATION SERVICE AND PARTS 7 7 Wiring Diagram...

Страница 9: ...X 1 25 2 pole Fuse 7 807 2819 Fuse 3ab 314 20 Amp 8 106 2790 Board HPT Controller 9 826 1549 Kit 208V Heater Replacement includes heater and acrylic tape 10 826 1551 Kit 208 240V Blower Replacement in...

Страница 10: ...FOR OUTDOOR USE WHEN OPERATING THIS UNIT IT MUST BE PLACED ON A HORIZONTAL SURFACE THE HEATED PASS THROUGH IS NOT SUITABLE FOR INSTALLATION IN AN AREA WHERE A WATER JET CAN BE USED THIS APPLIANCE MUS...

Страница 11: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 12: ...ort Louisiana 71135 1000 Shipping Address 8700 Line Avenue Shreveport Louisiana 71106 TEL 1 318 865 1711 FAX Parts 1 318 219 7140 FAX Tech Support 1 318 219 7135 Price 6 00 PRINTED IN THE UNITED STATE...

Отзывы: