3. HEATED LANDING ZONE 

 

The 

Heated Landing Zone

 or 

HLZ 

is designed to hold assembled sandwiches.  By circulating heated 

air evenly across the open staging area, the Heated Landing Zone keeps sandwiches hot without 
drying or cooking.  The Heated Landing Zone meets all McDonald’s standards for safety, efficiency, 
food safety, and cleanliness. 

 

4. INSTALLATION/SETUP 

 

Upon arrival, inspect the HLZ for concealed damage.  
Immediately report any damage to the delivering freight 
company.  Claims must be filed within 15 days after 
receipt of the unit. 

 

Make sure that the unit is placed on an even surface and 
that the area surrounding the HLZ is free of clutter that 
would interfere with air flow. 

 

INSTALL OPTIONAL BURGER BUMPER (Units built before 10/98) 

 

The burger bumper may be placed on either side of the 
HLZ to prevent pass through of product. Burger bumpers 
are provided by the KES. See figure 1. 

 

INSTALL FILTER SCREEN (Units built after 10/98) 

 

The filter screen is design to prevent debris from entering 
the Computer Cowl Assembly and clogging the blower 
assembly.  Simply fit the part on to the vent opening of the 
computer cowl assembly.  The filter screen will snap into 
position.  If equipped with an optional holding screw, 
tighten screw to pull the filter screen snug into position. 

 

 
 
POWER REQUIREMENTS: 

 

 

Voltage – Two models are available: 208 VAC and 240 VAC* 

 

Frequency - 60 Hz 

 Single 

Phase 

 

20 amp Service 

5. OPERATION 

 

1.

 

Plug the unit into the power source.* 

 

2.

 

See “

HLZ COMPUTER OPERATION AND 

PROGRAMMING, Section 7” 

for proper setup and 

operation of the computer.  

 

3.

 

Place product in the HLZ in accordance with the 
restaurant’s established procedures. 

 

4.

 

CLOSING

  - When closing the store, remove all product from the HLZ and perform daily preventive 

maintenance in accordance with the MRC. Turn the computer OFF. 

THIS APPLIANCE IS EQUIPPED WITH A 
GROUNDING PLUG FOR YOUR 
PROTECTION AGAINST SHOCK 
HAZARD AND MUST BE PLUGGED INTO 
A PROPERLY GROUNDED 
RECEPTACLE.  DO NOT CUT OR 
REMOVE THE GROUNDING PRONG 
FROM THIS PLUG. 

Figure 1 

Optional Burger Bumper 

Installed (unit built before 10/98)

Computer 

Cowl 

* If the 240 VAC model is operated on 
208 VAC, the unit will heat slowly and 
may not reach maximum temperature.  If 
the 208 VAC model is operated on 240 
VAC, component damage is probable.  
To ensure proper operation, the power 
source should match the voltage on the 
rating plate on the bottom of the HLZ. 

The filter screen snaps into place on rear of the 
air-intake tower. 

Содержание Heated Landing Zone HLZ 18

Страница 1: ...TED LANDING ZONE 1 1 2 PARTS RETURN 1 1 3 WARRANTY EXCLUSIONS 1 2 PARTS ORDERING AND SERVICE INFORMATION 2 3 HEATED LANDING ZONE 3 4 INSTALLATION SETUP 3 5 OPERATION 3 6 HLZ MODEL COMPONENT IDENTIFICA...

Страница 2: ...L SERVICE AND ACCESS PANELS ARE IN PLACE AND PROPERLY SECURED DO NOT ATTEMPT TO REPAIR OR REPLACE ANY COMPONENT OF THE HLZ SERIES UNLESS ALL POWER TO THE UNIT HAS BEEN DISCONNECTED USE CAUTION WHEN SE...

Страница 3: ...repair failure to follow proper installation instructions and or scheduled maintenance procedures as prescribed in your MRC cards improper maintenance damage in shipment abnormal use removal alterati...

Страница 4: ...on may be obtained by calling the Frymaster Service Department The following information will be needed in order to assist you quickly and efficiently Model Number _________________________ Serial Num...

Страница 5: ...ogging the blower assembly Simply fit the part on to the vent opening of the computer cowl assembly The filter screen will snap into position If equipped with an optional holding screw tighten screw t...

Страница 6: ...ine Page 4 1 800 24 FRYER 6 HLZ MODEL COMPONENT IDENTIFICATION Heated air flows from the air heater blower and heat rises from the heater plate Heater Plate Calibration Socket Air Heater Calibration S...

Страница 7: ...default is set to the McDonald s standard of 220 F If the factory default temperature settings are acceptable skip to Section 7 2 Page 6 Ensure that the HLZ computer is in the OFF position nothing in...

Страница 8: ...amming both heaters press the Check Switch again to store the programmed setpoints and exit the programming mode OR to change the setpoint temperature for the other heater press the corresponding Heat...

Страница 9: ...light in the display when either the heater plate or air heater is energized When the HLZ is ready for operation the display reads REdY ready Place product in the HLZ in accordance with the restaurant...

Страница 10: ...latching relay After 20 minutes of operation computer display shows PROB RTD probe has failed Isolate failed component by checking temperature of air and heater plate with the temperature display key...

Страница 11: ...le 208 240V 22 x12 806 9239 Line Filter CE 807 2818 Plug Assembly Computer 806 9636 Air Relay SS Service 826 2038 Plate Relay SS Service 826 1958 Relay Latching 807 3021 Blower 230V CE 807 3691 Blower...

Страница 12: ...l on the heater plate while troubleshooting 9 4 Replacing Solid State Relays a Avoid miswiring Examine the terminals carefully and take notes to avoid miswiring b Remove the plate holding the relay as...

Страница 13: ...of the front air delivery 9 6 Replacing Air Thermocouple and Air RTD Probe a Follow procedures in section 9 3 to access the Air Delivery tower components b Cut old lead wires close to the faulty air...

Страница 14: ...late and chassis f Remove acrylic tape from the heater plate and frame to prevent rebounding while servicing g When reinstalling the heater plate apply new acrylic tape to the HLZ chassis first Then p...

Страница 15: ...r i Slip the hi limit wires into the removed grommets and snap back into place j Plug the black wire leading from pin 1 in the computer plug into the terminal of the hi limit k Plug the other hi limit...

Страница 16: ...r delivery panel 4 Test fit the air delivery assembly to see if a gap is visible once the assembly is properly seated If a gap remains apply a second gasket to create a better seal 5 Make sure the bra...

Страница 17: ...sure DC voltage points to a problem with the computer or connection With power supplied and computer turned on measure AC voltage across output terminals of relay With computer calling for heat dot il...

Страница 18: ...isting on the resistance chart With the unit cool the resistance reading should approximate the resistance shown on the chart for the room temperature Also check for short to ground A chaffed wire sho...

Страница 19: ...age is applied Symptom Overheats Test With power removed from the HLZ measure resistance between pin 4 white wire on the latching relay and terminal 4 on the air heater relay The reading should be bet...

Страница 20: ...5 and 65 ohms Remove power from unit On 240V units disconnect red and white wires connecting blower to heat and latching relays The resistance between the wires should be between 62 and 72 ohms 10 10...