FilterQuick Controller Field Replacement for FilterQuick Models
2
Replacing the Controller
1.
Follow the steps in Section 1.4 in the provided manual to record the settings of the
replacement
controller
on the FilterQuick fryer.
Make a note of all settings (include all 20 buttons in
Product Set-up and Vat Set-Up to include System, Time/Date, DST and Filter). They will
have to be transferred to the new service controller.
2.
Disconnect the fryer from the electrical power supply.
3.
Open the control panel by removing the screws on the bottom of the bezel. Carefully lower the
bezel.
4.
Remove the two screws from the upper corners of the controller. The controller is hinged at the
bottom and will swing open from the top.
5.
Unplug the wiring harnesses from the connectors on the back of the controller, marking their
position for reassembly. Disconnect the ground wires from the terminals. Remove the controller,
lifting it from the hinged slots.
6.
Install the new replacement controller in the far most left position to
setup up the controller.
7.
Attach the ground wires and harnesses removed in step 5.
8.
Rotate the controller up and install one screw to position it for the
setup sequence.
9.
Follow the instructions below to setup the controller to match the settings recorded earlier from the
fryer bank’s leftmost controller.
Setup: FilterQuick Fryers
Left Display
Right Display
Action
OFF OFF
Press
until the controller scrolls Info Mode, changing to Main and then PRODUCT
SETUP.
Product
Setup
Blank Press
to scroll to Vat Setup. Press
.
Vat setup
Enter
code
Enter 1656
system
Press
.
Language English
Press
to scroll to another language. Press
.
2nd
Language
Spanish
Press
to scroll to another language.
Press
.
Locale Non-ce
Press
to change locale. Press
.
Energy gas
Press
to change to ELEC if necessary. Press
.
Type Gl30
full
Press
to scroll to GL30 Split (GL…OSP designations are for European usage.) if
necessary. Press
.
System
volume
5
Press
to change to setting recorded from fryer controller. Press
.
Temper
format
F
Press
to change to setting recorded from fryer controller. Press
.
Exit melt
TMPR
180F
Press
to change to setting recorded from fryer controller. Press
.
Ground Wire Terminal
20-Pin Connector
Ground Wire Terminal
Communication Wires
Locator Wire
NOTE:
The
rightmost
controller
will
also
have
an
end
‐
of
‐
line
resistor.
It
must
be
transferred
to
a
new
controller
occupying
the
rightmost
position.
Drain Switch
and LED