background image

FilterQuick Controller Field Replacement for FilterQuick Models 

 

 

Replacing the Controller

 

 

1.

 

Follow the steps in Section 1.4 in the provided manual to record the settings of the 

replacement 

controller

 on the FilterQuick fryer.  

Make a note of all settings (include all 20 buttons in 

Product Set-up and Vat Set-Up to include System, Time/Date, DST and Filter). They will 
have to be transferred to the new service controller.

   

2.

 

Disconnect the fryer from the electrical power supply. 

3.

 

Open the control panel by removing the screws on the bottom of the bezel. Carefully lower the 
bezel. 

4.

 

Remove the two screws from the upper corners of the controller.  The controller is hinged at the 
bottom and will swing open from the top. 

5.

 

Unplug the wiring harnesses from the connectors on the back of the controller, marking their 
position for reassembly. Disconnect the ground wires from the terminals. Remove the controller, 
lifting it from the hinged slots.  

 

 

6.

 

Install the new replacement controller in the far most left position to 
setup up the controller.   

7.

 

Attach the ground wires and harnesses removed in step 5. 

8.

 

Rotate the controller up and install one screw to position it for the 
setup sequence. 

9.

 

Follow the instructions below to setup the controller to match the settings recorded earlier from the 
fryer bank’s leftmost controller. 

 

Setup: FilterQuick Fryers

 

  

 

Left Display

 

Right Display

 

Action

OFF OFF 

Press 

 until the controller scrolls Info Mode, changing to Main and then PRODUCT 

SETUP.  

Product 
Setup 

Blank Press 

 to scroll to Vat Setup. Press 

Vat setup 

Enter 
code 

Enter 1656 

system  

Press 

.  

Language English 

Press 



 to scroll to another language. Press  

.  

 

2nd 
Language 

Spanish 

Press 



 to scroll to another language.

 

Press  

.  

 

Locale Non-ce 

Press 



 to change locale.  Press  

.  

 

Energy gas 

Press 



 to change to ELEC if necessary. Press  

.  

 

Type Gl30 

full 

Press 



 to scroll to GL30 Split (GL…OSP designations are for European usage.) if 

necessary.  Press  

.  

 

System 
volume 

Press 



 to change to setting recorded from fryer controller.  Press  

.  

 

Temper 
format 

Press 



 to change to setting recorded from fryer controller.  Press  

.  

 

Exit melt 
TMPR 

180F 

Press 



 to change to setting recorded from fryer controller.  Press  

.  

 

Ground Wire Terminal

20-Pin Connector

Ground Wire Terminal 

Communication Wires 

Locator Wire

NOTE:

 

The

 

rightmost

 

controller

 

will

 

also

 

have

 

an

 

end

of

line

 

resistor.

 

It

 

must

 

be

 

transferred

 

to

 

a

 

new

 

controller

 

occupying

 

the

 

rightmost

 

position.

 

Drain Switch 

and LED 