5-2
5.2
Operator Troubleshooting Guide
PROBLEM
POSSIBLE CAUSES
CORRECTIVE ACTION
A.
No power to unit.
A.
Turn on circuit breaker.
B.
Computer not turned on.
B.
Press computer ON/OFF key.
Computer does not
activate.
C. Main power switch off.
C. Turn main power switch on.
A.
Water not turned on.
A.
Turn water on.
B.
Upper float stuck in up
position.
B.
Clean float switch assembly (see
Section 4.1).
Autofill does not add
water.
C.
Malfunctioning solenoid
valve.
C.
Call ASA.
A.
Dirty/sticking upper float
switch.
A.
Clean float switch assembly (see
Section 4.1).
Autofill does not shut
off when the cookpot
is full.
B.
Malfunctioning solenoid
valve.
B.
Call ASA.
Water will not heat
(computer is on, water
is at normal level, but
LO
is not showing
on
the computer).
A.
Dirty/sticking lower float
switch.
A.
Clean float switch assembly (see
Section 4.1).
A.
Defective controller.
A.
Call ASA.
Water will not heat
(water above lower
water level sensor and
LO is showing on the
computer).
B.
Malfunctioning element
or other component in
heating system.
B.
Call ASA.
A.
Defective controller.
A.
Call ASA.
Water heats but does
not reach setpoint.
B.
Malfunctioning element.
B.
Call ASA
A.
Operator error.
A.
Push a product button.
Timer does not count
down.
B.
Defective controller.
B.
Call ASA