3-2
3.2 Controller
This equipment uses a specialized controller.
Computer Operation
•
Ensure the main power switch (behind cabinet door) is on.
•
Press either ON/OFF button to turn the computer on.
•
The computer displays LO as it rises to the preset 190°F setpoint for simmer.
•
At setpoint, the computer displays alternate between dashed lines and
S
inn
.
•
Press a Temperature key to toggle display to actual temperature on the left, setpoint on the
right. Press again to toggle back.
Simmer
•
Place product in vat and press desired timer key. Display alternates
between
S inn
and remaining cook time.
•
COOC
appears and an alarm sounds when the cook time elapses. Cook
cycles won’t start if the computer is displaying LO.
•
Remove the product and press the timer key to halt the alarm.
Boil
•
Press the boil key.
•
Display changes to
boil.
•
Wait until water boils.
•
Place product in vat and press the desired timer key.
Temperature keys are inactive.
•
Display alternates between boil and the remaining
cook time.
•
COOC
appears and an alarm sounds when the cook time elapses.
•
Remove the product and press the timer key to halt the alarm.
NOTE:
Computer re-
turns to simmer mode
if a boil cook cycle is
not initiated within 15
minutes of pressing
the boil key.
NOTE:
Pressing the Boil key with
the computer OFF produces a
CodE
display, which is used in ini-
tial programming. ON/OFF keys
are inactive. Press any other key
four times to clear display and
reactivate ON/OFF keys.