![Frymaster BIPH55 Series Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/frymaster/biph55-series/biph55-series_operators-manual_2340412023.webp)
3-4
3.1.3 Shutdown
For short-term shut down during the workday:
1.
Place the computer ON/OFF switch in the
OFF
position and put the frypot covers in place.
When shutting the fryers down at closing time:
1.
Place the computer ON/OFF switch in the
OFF
position to turn the fryer off.
For Non-CE Fryers
After placing the ON/OFF switch in the OFF
position, turn the gas valve knob to the OFF
position.
Hone
yw
el
l
ON
OF
F
Hone
yw
el
l
ON
OF
F
For CE Fryers
Placing the ON/OFF switch in the OFF
position also turns off the gas valve.
2.
Filter the oil and clean the fryers (See Chapters 4 and 5).
3.
Place the frypot covers on the frypots.
3.2
Boiling Out the Frypot
To ensure that the frypot is free of any contamination resulting from its manufacture, shipping, and
handling during installation, the frypot must be boiled out before first use. Refer to Drain and Clean
Frypot (page 5-2) for this procedure.
3.3 Operation
This fryer is equipped with M2000 computers (illustrated below). Refer to the separate
M2000 Com-
puter Operating Instructions
furnished with the fryer for the computer programming and operating
procedures.
M2000 COMPUTER