Frymaster BIPH55 Series Скачать руководство пользователя страница 14

2-4

 

 DANGER

 

The appliance area must be kept free and clear of combustible material at all times. 

 

3.

 

Frymaster recommends that the minimum distance from the flue outlet to the bottom edge of the 
hood be 24 in. (600 mm) when the appliance consumes more than 120,000 BTU per hour.   

NOTE:

  There are no built-in leveling devices on fryers equipped with casters.  The floor where 

the fryer is to be installed must be level. 

4.  Test the fryer electrical system: 

 

a.

 

Plug the fryer electrical cord(s) into a grounded electrical receptacle. 

NOTE: To ensure the 

safe and efficient operation of the fryer and hood, the electrical plug for the 120-volt 
line, which powers the hood, must be fully engaged and locked in its pin and sleeve 
socket.  

 

b.  Place the power switch in the 

ON

 position. 

 

 

For fryers having computers, verify that the display indicates 

OFF

 

If the store is equipped with a hood interlock system, the hood exhaust fan should be on.  
If not, the store hood interlock system is improperly wired and must be corrected. 

 

c.

 

Place the fryer power switch in the 

OFF 

position.  Verify that the power and heat lights are 

out. 

 
5.

 

Refer to the data plate on the inside of the fryer door to determine if the fryer burner is 
configured for the proper type of gas before connecting the fryer quick-disconnect device or 
piping from the gas supply line. 

 
6.

 

Verify the minimum and maximum gas supply pressures for the type of gas to be used in 
accordance with the accompanying tables. 

Orifice Diameter

Single

Vat

Dual

Vat

Single

Vat

Dual

Vat

G20

20

2 x 3.40 2 x 3.40

7 mbar

7 mbar

G25

20 or 25

2 x 3.40 2 x 3.40

10 mbar

10 mbar

G30

28/30 or 50

2 x 2.05 2 x 2.05

17 mbar

17 mbar

G31

37 or 50

2 x 2.05 2 x 2.05

20 mbar

20 mbar

CE Standard

for Incoming Gas Pressures

for Fryers Manufactured After April 1999

(1) mbar = 10,2 mm H

2

O

Gas

Pressure

(mbar)

(1)

Regulator Pressure

  

 

Содержание BIPH55 Series

Страница 1: ...Shreveport Louisiana 71135 1000 TEL 318 865 1711 FAX Parts 318 219 7140 Tech Support 318 219 7135 PRINTED IN THE UNITED STATES SERVICE HOTLINE OCTOBER 2005 1 800 24 FRYER www frymaster com Email servi...

Страница 2: ...basic plumbing code of the Building Officials and Code Administrators International Inc BOCA and the Food Service Sanitation Manual of the U S Food and Drug Administration NOTICE Drawings and photos...

Страница 3: ...or other reproductive harm Operation installation and servicing of this product could expose you to airborne particles of glasswool or ceramic fibers crystalline silica and or carbon monoxide Inhalat...

Страница 4: ...pot replacement Components that are not part of the frypot assembly such as the blower gas valve micro switches doors and cabinetry are not covered by the frypot warranty If the frypot is found to be...

Страница 5: ...ANTY EXCLUSIONS This warranty does not cover equipment that has been damaged due to misuse abuse alteration or accident such as improper or unauthorized repair including any frypot which is welded in...

Страница 6: ...nd can be purchased as single units or in batteries of up to five fryers Pro Series H55 high efficiency gas fryers employ a unique infrared burner system that uses up to 43 less energy to cook the sam...

Страница 7: ...er ignition with the drain valve even partially open 1 3 Computer Information for the M2000 Computers FCC COMPLIANCE This equipment has been tested and found to comply with the limits for a Class A di...

Страница 8: ...ersonnel are those who have carefully read the information in this manual and have familiarized themselves with the equipment functions or who have had previous experience with the operation of the eq...

Страница 9: ...ntainer is retained for inspection Frymaster DOES NOT ASSUME RESPONSIBILITY FOR DAMAGE OR LOSS INCURRED IN TRANSIT 1 8 Parts Ordering and Service Information For non routine maintenance or repairs or...

Страница 10: ...5 1711 When requesting service please have the following information ready Model Number Serial Number Type of Gas In addition to the model number serial number and type of gas please be prepared to de...

Страница 11: ...ons installation and operation shall comply with the codes or regula tions in force in the country in which the equipment is installed DANGER Building codes prohibit a fryer with its open tank of hot...

Страница 12: ...a drip tray beneath the lowest edge of the filter For U S installation NFPA standard No 96 states A minimum distance of 18 in 450 mm should be maintained between the flue outlet and the lower edge of...

Страница 13: ...pon the specific configuration ordered your fryer may have been shipped without installed casters DO NOT INSTALL THIS APPLIANCE WITHOUT CASTERS If the appliance requires the installation of casters in...

Страница 14: ...indicates OFF If the store is equipped with a hood interlock system the hood exhaust fan should be on If not the store hood interlock system is improperly wired and must be corrected c Place the frye...

Страница 15: ...ve s DANGER All connections must be sealed with a joint compound suitable for the gas being used and all connections must be tested with a solution of soapy water before light ing any pilots Never use...

Страница 16: ...PRESSURE MBAR G20 20 AUSTRIA AT II2H3B P G30 G31 50 I2E R B G20 G25 20 25 BELGIUM BE I3 G30 G31 28 30 37 G20 20 DENMARK DK II2H3B P G30 G31 30 G20 G25 20 25 II2Esi3 G30 G31 28 30 37 G20 G25 20 25 FRAN...

Страница 17: ...er drain valve and fill the frypot with water and boil out solution to the bottom OIL LEVEL line at the rear of the frypot Light the fryer and perform the boil out procedures that are described in the...

Страница 18: ...his appliance from one type of gas to another should only be performed by qualified licensed and authorized installation or service personnel as defined in Section 1 6 of this manual Pro Series H55 ga...

Страница 19: ...the corner of the label 2 6 After the Fryers Are Positioned At the Frying Station 1 Once the fryer has been positioned at the frying station use a carpenter s level placed across the top of the frypo...

Страница 20: ...BIPH255 SHOWN NOTE The appearance of your fryer may differ slightly from that shown depending upon configuration and date of manufacture Flue Top Cap Gas Valve Control Panel M2000 Computer Shown Gas V...

Страница 21: ...to the bottom of the frypot 3 1 1 Setup WARNING Never operate this appliance with an empty frypot The frypot must be filled with wa ter or oil shortening before lighting the burners Failure to do so w...

Страница 22: ...for a longer period When the frypot temperature reaches 180 F 82 C the unit will automatically switch to the heating mode The burners will remain lit until the frypot temperature reaches the programme...

Страница 23: ...OFF switch in the OFF position also turns off the gas valve 2 Filter the oil and clean the fryers See Chapters 4 and 5 3 Place the frypot covers on the frypots 3 2 Boiling Out the Frypot To ensure tha...

Страница 24: ...in handles are in their proper position before operating any switches or valves Wear all appropriate safety equipment when draining and filtering oil DANGER Allow oil to cool to 100 F 38 C before drai...

Страница 25: ...fresh oil or solid shortening to the bottom OIL LEVEL line DANGER When using solid shortening pack the shortening down into the bottom of the frypot DO NOT operate the fryer with a solid block of shor...

Страница 26: ...back into the fryer positioning it all the way to the back of the cabinet The filtration system is now ready for use 4 4 Operation of the Filter DANGER Draining and filtering of oil must be accomplis...

Страница 27: ...hing Polishing cleans the oil by trapping solid particles in the filter pad 4 After the oil is filtered about 5 minutes close the drain valve and allow the fryer to refill Let the filter pump run 15 t...

Страница 28: ...n appropriate container for transport to the disposal container Frymaster recommends the use of the McDonald s Shortening Disposal Unit MSDU NOTE If using an MSDU built before January 2004 the filter...

Страница 29: ...ose or frayed wires and cords leaks foreign material in frypot or inside cabinet and any other indications that the fryer and accessories are not ready and safe for operation 5 2 2 Clean Fryer Cabinet...

Страница 30: ...ER Never operate the appliance with an empty frypot The frypot must be filled with water oil or shortening before lighting the burners Failure to do so will damage the frypot and may cause a fire 5 3...

Страница 31: ...esult from such scrubbing make subsequent cleanings more difficult 5 4 MONTHLY CHECKS AND SERVICE 5 4 1 Check M2000 Computer Set Point Accuracy 1 Insert a good grade thermometer or pyrometer probe int...

Страница 32: ...or with plastic wrap to prevent water from entering it Spray degreaser or detergent on the blower wheel and the blower housing Allow it to soak for five minutes Rinse the wheel and housing with hot ta...

Страница 33: ...nifold pressure is in accordance with the applicable table on page 2 7 and the burners display a bright orange red glow If a blue flame is observed or if there are dark spots on a burner face the air...

Страница 34: ...nspection This appliance should be inspected and adjusted periodically by qualified service personnel as part of a regular kitchen maintenance program Frymaster recommends that a Factory Authorized Se...

Страница 35: ...tainer and cleaned daily Verify that all O rings and seals are present and in good condition Replace O rings and seals if worn or damaged Check filtration system integrity as follows Verify that filte...

Страница 36: ...inues to blow find out why Always keep in mind that failure of a small component may often be indicative of potential failure or incorrect functioning of a more important component or system If you ar...

Страница 37: ...the drain valve s completely then press the ON OFF switch on B Gas valve is not turned on B Turn the gas valve knob to the ON position C Manual gas shut off valve closed C Verify that any in line man...

Страница 38: ...play Problems Problem Probable Causes Corrective Action M2000 display is in wrong temperature scale Fahrenheit or Celsius Incorrect display option programmed M2000 computers may be programmed to displ...

Страница 39: ...led computer failed transformer open high limit thermostat This indicates that the fryer is not heating It is displayed if the fryer loses its ability to heat oil It is also displayed when the oil tem...

Страница 40: ...h the pump was overheated Always filter with the cooking oil shortening at or near frying temperature Allow the pump motor to cool off for about ten minutes after filtering two full frypots one after...

Страница 41: ...nd that the crumb screen is used A Cooking oil is too cold for filtering A To properly filter the oil should be at or near 350 F 177 C At temperatures lower than this the oil becomes too thick to pass...

Страница 42: ...Remove the controller by lifting it up and out from the hinge slots in the control panel frame 8 Re hinge the NEW controller by inserting the tabs on the bottom into the slots on the control frame pa...

Страница 43: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 44: ...Shreveport Louisiana 71135 1000 Shipping Address 8700 Line Avenue Shreveport Louisiana 71106 TEL 1 318 865 1711 FAX Parts 1 318 219 7140 FAX Tech Support 1 318 219 7135 PRINTED IN THE UNITED STATES SE...

Отзывы: