Fryka KBT 02-51 Скачать руководство пользователя страница 7

 

 

TECHNICAL DATA 

 
Measuring Input 
F1:

 

Resistance thermometer Pt100 

 

Measuring range: -80...400°C 

 

Measuring accuracy: +/- 1K or +/- 0,5%  

 

of scale range, which ever is greater 

 

Output 
K1:

 

Relay, changeover contacts, 12A 250V  

 

Display 

One 3-digit, 13 mm high, red LED display 
 

Power Supply 

230V, 50Hz / 60Hz, current consumption max. 20mA 
 

Installation Data 

Front panel: 

84 x 42 mm  

Panel cut out: 

68 x 32 mm 

Depth:   

approx. 85 mm incl. terminals 

Mounting: 

fixing strap 

 

Enclosure 

Front IP65  
 

Weight 

approx. 200g 
 

Ambient Conditions 

Storage temperature: 

-20...+70 °C 

Operating temperature:  0...+55 °C  
Relative Humidity: 

max. 75% without dew 

 
 

 

    Hybrid
250V~  16A

  F1
Pt100

1    2    3   4   5   6   7   8   9   10 11 12

E1

 230 V
50/60Hz

Summer

 

 
Wiring diagram ~ 

Содержание KBT 02-51

Страница 1: ...tions Serial products and custom made coolers Instruction Manual Mini Chest Freezer KBT 02 51 V 101207 FRYKA K ltetechnik GmbH Ohmstr 4 Phone 0049 711 310599 0 D 73730 Esslingen Fax 0049 711 310599 29...

Страница 2: ...nt control with digital display setpoint control SET key and PT 100 internal temperature sensor Precise to 1 0K Control shows actual value when unit switched on To set the setpoint press the SET key a...

Страница 3: ...1 F1 Refrigerant R 507 x Terminal PE N L N1 L1 L2 1 2 PE Quantity 120 gr Voltage 230 V 50 Hz Current 1 5 A Parts List M 1 Compressor TL5G V 1 Fan 4715MS W 1 Condenser FCE 12 1 180 Ft Filter Drier 10 6...

Страница 4: ...the display changes to show the Control Set point UP key With the UP key it is possible to start a manual defrost DOWN key With the DOWN key it is possible to cancel the alarm buzzer First level Set p...

Страница 5: ...quipped with semiconductor relays Setpoint T t symmetrical hysteresis Heating or cooling control Figure 1 T t pos Hysteresis Setpoint Cooling control Figure 2 P4 Control range limitation minimum Set p...

Страница 6: ...me interval between the start of successive defrosting periods The initial start time is determined by the time of Mains on Defrosting can be initiated by interrupting the defrosting interval in advan...

Страница 7: ...LED display Power Supply 230V 50Hz 60Hz current consumption max 20mA Installation Data Front panel 84 x 42 mm Panel cut out 68 x 32 mm Depth approx 85 mm incl terminals Mounting fixing strap Enclosure...