Alarm "on"

Alarm "off"

Alarm "off"

Alarm "on"

Setpoint

upper boundary ( relative )

lower boundary ( relative )

 

 

 

Figure 3 

 

Range alarm function

 (see Figure 4) 

Opposite switching behaviour to the boundary value alarm LED 3 is illuminated and/or K3 is closed if the process 
temperature remains  between the boundary values. 

T

t

Alarm "off"

Alarm "on"

Alarm "on"

Alarm "off"

upper boundary  ( absolut )

lower boundary ( absolut )

Setpoint

 

 

 

Figure 4 

 

P32: Hysteresis alarm

 

The hysteresis for the alarm is always to one side of the Set point .  
It is below the Set point in the upper value and above the Set point for the lower value. 
 

d0 Defrost interval 

This parameter determines the time interval between the start of successive defrosting periods. The initial start time is 
determined by the time of "Mains on". 
Defrosting can be initiated by interrupting the defrosting interval in advance by a manual defrost. (Press the "UP-button 
for a minimum of 3 seconds) 
 

d2 Defrost temperature 

If the actual temperature is above this value defrosting ends. 
 

d3 Defrost time limit 

Defrosting ends latest as set here. 
 
 
 

Error codes 

 

Display 

error 

What to do 

F1L 

sensor short circuit 

new sensor 

F1H 

sensor failure 

new sensor 

F3L 

Boundary alarm 

Temperature low 

F3H 

Boundary alarm 

Temperature high 

F4 

Alarm at connection E1 

Liquid level sensor alarm --- control level of cooling liquid  

--- 

Keyboard lock active 

see Parameter P19 or A19 

display flashing, 
buzzer 

Temperature alarm  
(see A31) 

cancel buzzer  
with 

 button 

EP 

lost of data  
in EE-Prom 

repair of controller 

 

 

Содержание KBT 02-51

Страница 1: ...tions Serial products and custom made coolers Instruction Manual Mini Chest Freezer KBT 02 51 V 101207 FRYKA K ltetechnik GmbH Ohmstr 4 Phone 0049 711 310599 0 D 73730 Esslingen Fax 0049 711 310599 29...

Страница 2: ...nt control with digital display setpoint control SET key and PT 100 internal temperature sensor Precise to 1 0K Control shows actual value when unit switched on To set the setpoint press the SET key a...

Страница 3: ...1 F1 Refrigerant R 507 x Terminal PE N L N1 L1 L2 1 2 PE Quantity 120 gr Voltage 230 V 50 Hz Current 1 5 A Parts List M 1 Compressor TL5G V 1 Fan 4715MS W 1 Condenser FCE 12 1 180 Ft Filter Drier 10 6...

Страница 4: ...the display changes to show the Control Set point UP key With the UP key it is possible to start a manual defrost DOWN key With the DOWN key it is possible to cancel the alarm buzzer First level Set p...

Страница 5: ...quipped with semiconductor relays Setpoint T t symmetrical hysteresis Heating or cooling control Figure 1 T t pos Hysteresis Setpoint Cooling control Figure 2 P4 Control range limitation minimum Set p...

Страница 6: ...me interval between the start of successive defrosting periods The initial start time is determined by the time of Mains on Defrosting can be initiated by interrupting the defrosting interval in advan...

Страница 7: ...LED display Power Supply 230V 50Hz 60Hz current consumption max 20mA Installation Data Front panel 84 x 42 mm Panel cut out 68 x 32 mm Depth approx 85 mm incl terminals Mounting fixing strap Enclosure...

Отзывы: