9.  CABINET IMPEDANCE – When one or both of the two parallel jacks are connected, simply set the 

impedance selector switch for connection according to the chart below:

  16Ω + None = 16Ω, 
  16Ω + 16Ω = 8Ω, 
  8Ω + None = 8Ω
  8Ω + 8Ω = 4Ω
  4Ω + None = 4Ω

 A SPEAKER MUST ALWAYS BE PLUGGED INTO ONE OF THESE JACKS WHEN THE AMPLI-

FIER IS ON OR DAMAGE MAY OCCUR. SWITCH THE AMPLIFIER OFF OR TO STANDBY WHEN 

CHANGING SPEAKER CONNECTIONS OR IMPEDANCE SETTINGS.

10. GROUND LIFT – This switch separates the internal circuit ground from chassis and power ground 

in order to eliminate possible ground loops between the Power Station and the load amplifier 

connected to the AMP IN jack. Select the position which yields quietest operation. With a properly 

wired AC outlet and factory supplied AC cord, this switch may not produce a noticeable difference.

11. MAINS FUSE – Protects the amplifier from electrical faults. Replace only with type and rating spe-

cified on the rear panel of your amplifier.

12. AC MAINS INPUT – Connect to a grounded outlet in accordance with the voltage and frequency 

specified on the rear panel of your amplifier. 

 USE ONLY THE FACTORY SUPPLIED CORDSET OR A UL APPROVED EQUIVALENT TYPE

TUBE FUNCTION AND LOCATION

Power and phase inverter tubes are mounted horizontally near the back of the unit. The power tubes are 

factory biased for optimum performance. No provision for internal or external biasing is provided. To insu-

re that the Power Station will remain within safe temperature operating limits, the bias must not be mo-

dified or tampered with. Doing so will immediately void the warranty. Tube types are factory selected for 

superior performance, consistent tone quality and reliability. Power tubes are factory tested and matched. 

For best performance, replace only with factory recommended tubes.

 TO REDUCE THE RISK OF ELECTRIC SHOCK, PLEASE REFER SERVICING TO QUALIFIED 

SERVICE PERSONNNEL. NO USER SERVICABLE PARTS INSIDE.

V1 – 12AX7 Power amplifier driver and phase inverter.
V2, V3 – 6L6 Power tubes.

 USE ONLY 6L6 OR EQUIVALENT.  NOT INTERCHANGEABLE WITH ANY OTHER TUBE TYPES!

Any type or brand of 6L6 can be used in this amplifier without adjustment or modification.
It is important to keep the amplifier on standby during breaks, and powered down when not in use to keep 

things cool and to extend tube life.
Even though you may follow this advice carefully, you will still observe that the amplifier tends to run hot 

during use. 

This is normal

 and there is not only a cooling fan and plenty of ventilation in the chassis  

design, but all of the critical components and transformers are designed to withstand much more heat 

than you will normally experience at during typical operation.

Содержание PowerStation PS1

Страница 1: ...Power Station OWNERS MANUAL VARIABLE REACTIVE LOAD TUBE POWER AMPLIFIER MODEL PS1 www fryette com...

Страница 2: ......

Страница 3: ...attenuator and re amplification solution offering players intuitive and precise control over amplifier volume distortion behavior and a wide range of highly refined tonal qualities previously unavail...

Страница 4: ...n dropped or the enclosure damaged X X Do not drip or splash liquids nor place liquid filled containers on the unit X X CAUTION No user serviceable parts inside refer servicing to qualified personnel...

Страница 5: ...in your live or recorded mix 2 DEEP WARM FLAT This switch sets the low frequency Bass Resonance response of the reactive load in the Power Station This will determine how much of your load amplifier...

Страница 6: ...the Power Station internal power amp 5 FX LEVEL This sets the signal level inside the loop Use the HI position for line level 4 to 0dB devices Use the LO position for guitar level devices 10 to 20dB...

Страница 7: ...zontally near the back of the unit The power tubes are factory biased for optimum performance No provision for internal or external biasing is provided To insu re that the Power Station will remain wi...

Страница 8: ...LACE ONLY WITH SAME TYPE FUSE UTILISER UN FUSIBLE DE ECHANGE DE MEME TYPE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL NO USER SERVICABLE PARTS INSIDE HI LO MAINS INPUT SPKR OUT GROUND LIFT POWER ST...

Страница 9: ...EQUIPMENT TO RAIN OR MOISTURE CAUTION REPLACE ONLY WITH SAME TYPE FUSE UTILISER UN FUSIBLE DE ECHANGE DE MEME TYPE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL NO USER SERVICABLE PARTS INSIDE HI LO...

Страница 10: ...connected RUNNING HOT 1 Make sure that the unit has adequate ventilation 2 Make sure that the impedance selector is set to the proper impedance 3 Power tubes may be drawing excessive current refer to...

Страница 11: ...ective EC1907 206 for the Registration Evaluation Authorization and Restriction of chemicals REACh and contain none or less than 0 1 of the chemicals listed as hazardous chemicals in the REACh regulat...

Страница 12: ...essitated by any cause beyond the control of SFD including but not limited to any malfunction defects or failure caused by or resulting from unauthorized service or parts damaged or broken tubes incor...

Отзывы: