INSTALLATION AND MAINTENANCE MANUAL
TRANSLATION OF THE
ORIGINAL DOCUMENT
For additional copies visit:
www.frost-trol.com
GREGAL
SOLID LINES
D008270
Versión: 2
-11-
It’s mandatory to leave 8cm between the cabinet rear wall and the
supermarket wall to ensure the airflow.
2.2.
UPACKING
Unpacking is reserved for skilled personnel.
The refrigerated cabinet is protected by plastic wrapping. Remove this and take out
the accessories which can be found inside the cabinet:
Using a fork-lift truck or pallet-lift, lift the cabinet, remove the wooden or plastic
supports and replace them with the plastics bases that can be found inside the
cabinet with the other accessories.
Packaging materials (plastic bags, nails, screws, polystyrene, etc.)
should not be left within reach of children as they pose potential
sources of danger.
2.3.
LEVELLING
Use the adjustable bases to level the unit. Poor levelling could result in problems
with the defrost-water drainage, which could then freeze and thus cause the unit to
break down.
Poor levelling could result in problems with the drainage of water
resulting from defrosting, which could cause the unit to break down.
IMPORTANT!
The surfaces that the lines are to be placed on may not be perfectly horizontal.
Therefore it would be best to first take the section of line that is to be placed onto
the highest part of the surface and screw its adjustable bases to their smallest
possible heights whilst allowing the section to remain horizontal. This will ensure
that the bases on the end sections do not need to be excessively extended.
2.4.
INSTALLATING THE DRAINAGE SISTEM
An incorrect installation of the wastepipes system can interfere negatively in the
regular activities of the storekeeper and produces unnecessary costs of
maintenance and product damages.
The siphons should be installed as near to the unit's opening as possible. The tubes
should be secured so that the siphons do not have to support their entire weight.