Manual Revision Code: FRONTLINE-SRL-04 10-19-20
6
Body Support:
A full body harness must be worn when using SRL. Connect the SRL to the user's harness shoulder straps
the back (dorsal) D-ring.
Be noted that the Dual SRLs are connected by the dual connector. When connecting it to harness, the
connector should be connected on the web loop of the back harness not on the D-ring.
Frontline friendly reminder-
Do not use a body belt for free fall applications. Per OSHA 1926.502 requirement.
Making Connections:
Snap hooks and carabiners used with this equipment must be self-locking. Ensure all connections are
compatible in size, shape, and strength. Do not use equipment that is not compatible. Ensure all connectors
are fully closed and locked, ensure unintended disengagement cannot occur.
Frontline connectors (snap hooks and carabiners) are designed to be used only as specified in each
product’s user’s instruction.
Inspection:
Before each use of this fall protection equipment carefully inspect it to assure it is in good working
condition. Check for worn or damaged parts. Ensure all bolts are present and secure. Check that the lifeline
is retracting properly by pulling out the line and allowing it to slowly retract. If there is any hesitation in
retraction, remove the SRL from service, mark " UNUSABLE". Inspect the lifeline for cuts, frays, burns,
crushing and corrosion. Check to lock action by pulling sharply on the line.
Product Life:
The functional life of SRL is determined by work conditions and maintenance. As long as the SRL passes
inspection criteria, it may remain in service.
Disposal:
Dispose of SRL if it has been subjected to fall arrest forces or inspection reveals an unsafe or defective
condition. Before disposing of the SRL, cut the cable lifeline in half or otherwise disable the SRL to eliminate
the possibility of inadvertent reuse.
MAINTENANCE, SERVICING, AND STORAGE
Cleaning: Cleaning procedures for SRL are as follows:
Ensure the SRL is kept free of excess paint, grease, dirt or other contaminants as this may cause to cable or
retracting mechanism to malfunction. Ensure no debris enters the housing through the cable access port.
Clean the exterior of the unit as required with a detergent/water solution. Do not allow water other