background image

Frontline Technical Support: Phone +1-434-984-4500 or email [email protected]

l

Use two high-speed computers, one for the ComProbe analyzer software and one—the

Target Host

—for the device under test .

o

Although it is possible to use one computer for both the analysis and test computer, this configuration requires that the computer in use is high-
speed and has two or more host controllers available.

l

Use USB 2.0 connections.

l

Use cables that do not exceed the recommended maximum length.

o

The cable connected to the analysis computer—

Analysis PC

—should not exceed 5 meters (15 feet).

o

The combined length of cables connected to the test computer—

Target Host

—and the device under test—

Target Device

—should not exceed

3 meters (9 feet).

Connect a USB cable between the device under test and the ComProbe hardware

Target Device

connector.

Connect a USB cable between the test computer and the ComProbe hardware

Target Host

t connecter.

Connect a USB cable between the analysis computer and the ComProbe hardware

Analysis PC

connector.

If the operating system encounters an error when trying to install the ComProbe device, disconnect the device, then reconnect it and try again.

3 Select Data Caputre Method

Now that the software and drivers are installed and the hardware is positioned correctly, the
next step is to open ComProbe software and select the data capture method.

Open the "Frontline ComProbe Protocol Analysis System" folder from the Start menu or from
the Desktop folder.

Select "Frontline ComProbe Protocol Analysis System".

The

Select Data Capture Method

dialog appears.

Select USB

Click the

Run

button.

ComProbe software will open with the

Control

window (See "Select Data Caputre Method"

on page 2) visible.

4 Hardware Settings

The

Hardware Settings

dialog is used to select a device to sniff/scan. To access the

Hardware

Settings

dialog:

Select

Hardware Settings

from the

Options

menu on the

Control

window .

Select a "device" from the drop-down list and select

OK

. By default the connected ComProbe

USB device will be shown.

If no devices are found, the list will be blank. You can also select

Refresh List

to make sure the

list is up to date.

5 Start Capture

So, now that the ComProbe SD hardware is installed, devices turned on and identified. It's time to sniff the communication
between the devices.

Select

Start Capture

on the

Control

window toolbar or from the

Control

window

Live

menu.