37
EN
Troubleshooting
"Wire end" error
message
The "wire end" error message is used for the following errors on VR 1500 series systems:
-
wire end
-
overheating of power electronics
-
motor current too high
"Wire end" spe
-
cial function
Two options can be preset on the power source for the "wire end" error message:
(1)
complete welding ... e.g. for short weld seams
(2)
stop welding immediately ... e.g. for long weld seams, flux core wire applications,
high-performance welding (risk of motor power module overload if these welding
processes are not stopped)
Troubleshooting
Err | 056 (on the power source)
Wire end
Cause:
The wire end check option has detected the end of the welding wire.
Remedy:
Insert new wirespool and thread in the welding wire, acknowledge the error
on the power source
Cause:
Additional fan filter is contaminated - air supply for the additional fan is no
longer sufficient to cool the power electronics - the power electronics temper
-
ature switch has tripped
Remedy:
Clean filter or replace, acknowledge the error on the power source
Cause:
Ambient temperature too high
Remedy:
Reduce ambient temperature, if necessary position and operate the welding
system at a cooler location; acknowledge the error on the power source
Cause:
Motor current too high e.g. due to wire threading problems or an inadequately
dimensioned wirefeeder
Remedy:
Check wire threading conditions, rectify faults, acknowledge error on the pow
-
er source
Error reset
Press the "Setup/Store" button on the power source to acknowledge an er
-
ror message. Setup/Store button on the power source
Setup/Store button on the power source