C-t
Cooling Time
(only with connected cooling unit)
Time from when flow monitoring is triggered until the "no | H2O" service code
is output. For example, if there are air bubbles in the cooling system, the cool-
ing unit will not cut out until the end of this preset time.
Unit: s
Setting range: 5 - 25
Factory setting: 10
IMPORTANT!
Every time the power source is switched on, the cooling unit
carries out a test run for 180 seconds.
SEt
Setting - country-specific setting (Standard/USA), etc. Std/US
Unit: -
Setting range: Std, US (Standard/USA)
Factory setting:
Standard version: Std (measurements: cm/mm)
USA version: US (measurements: inches)
r
r (resistance) - welding circuit resistance (in mOhm)
see "Measuring welding circuit resistance r"
L
L (inductivity) - welding circuit inductivity (in microhenry)
see "Displaying welding circuit inductivity L"
EnE
Real Energy Input – electrical energy of the arc relative to the welding
spee
Unit: kJ
Setting range: ON / OFF
Factory setting: OFF
Since the full range of values (1 kJ - 99999 kJ) cannot be displayed on the
three-digit display, the following display format has been selected:
Value in kJ / indicator on display:
1 to 999 / 1 to 999
1000 to 9999 / 1.00 to 9.99 (without "ones" digit, e.g. 5270 kJ -> 5.27)
10000 to 99999 / 10.0 to 99.9
(without "ones" and "tens" digits, e.g. 23580 kJ -> 23.6)
ALC
Arc Length Correction - correction of the arc length via the welding
voltage
Setting range: ON / OFF
Factory setting: OFF
The arc length depends on the welding voltage. the welding voltage can be
adjusted to suit individual needs in Synergic operation.
If the ALC parameter is set to "OFF", the welding voltage cannot be adjusted.
The welding voltage is automatically determined by the selected welding cur-
rent or wire speed. If the arc length correction is adjusted, the voltage
changes, but the welding current and wire speed remain the same. When set-
ting the arc length correction using the adjusting dial, the left display is used
for the correction value of the arc length. The welding voltage value on the
right display changes simultaneously. Afterwards the left display shows the
original value, e.g. welding current.
88
Содержание TransSteel 2700c
Страница 2: ......
Страница 18: ...18...
Страница 19: ...General information 19...
Страница 20: ...20...
Страница 26: ...VRD is active again The output voltage is limited to 35 V once more 26...
Страница 27: ...Control elements and connections 27...
Страница 28: ...28...
Страница 37: ...Installation and commissioning 37...
Страница 38: ...38...
Страница 62: ...62...
Страница 63: ...Welding 63...
Страница 64: ...64...
Страница 78: ...Number 2 Number 3 Number 4 Number 5 78...
Страница 79: ...Setup settings 79...
Страница 80: ...80...
Страница 91: ...10 Fit the gas nozzle back onto the welding torch 91 EN...
Страница 93: ...Troubleshooting and maintenance 93...
Страница 94: ...94...