26
Technical data
Safety
Generator-pow-
ered operation
The power sources in the TP 2500/3500 series are totally generator-compatible, provided
that the maximum apparent power delivered by the generator is at least 14 kVA for the TP
2500 or 22 kVA for the TP 3500.
TransPocket
2500, 2500 RC,
2500 TIG
NOTE!
An inadequately dimensioned electrical installation can cause serious
damage. The mains lead and its fuse protection must be rated accordingly. The
technical data shown on the rating plate applies.
Mains voltage (U
1
)
3 x
380 V
400 V
460 V
Max. effective primary current (I
1eff
)
10.5 A
10.1 A
8.6 A
Max. primary current (I
1max
)
17.7 A
17.0 A
14.6 A
Mains fuse protection
16 A slow-blow
Mains voltage tolerance
-10% / + 10%
Grid frequency
50/60 Hz
Cos phi (1)
0.99
Recommended residual-current circuit breaker
Type B
Welding current range (I
2
)
MMA
15 - 250 A
TIG
15 - 250 A
Welding current at
10 min/40 °C (104 °F)
40%
60%
100%
250 A
200 A
175 A
Output voltage range according to standard characteristic
(U
2
)
MMA
20.6 - 30 V
TIG
10.6 - 20 V
Open circuit voltage (U
0
peak, U
0
r.m.s)
88 V
Open circuit voltage VRD
12 V
Degree of protection
IP 23
Type of cooling
AF
Overvoltage category
III
Pollution level according to IEC60664
3
Safety symbols
S, CE
Dimensions l x w x h
430 x 180 x 320 mm
16.9 x 7.1 x 12.6 in.
Weight
12.5 kg
27.5 lb.
Max. shielding gas pressure (TIG)
5 bar
72.5 psi.
Max. noise emission (LWA)
74 dB (A)