Setup regula-
tions
WARNING!
Danger from system components falling or toppling over.
This can result in severe personal injury and damage to property.
▶
After delivery, remove the device from the pallet as described in the "Remov-
ing the pallet" section.
▶
Set up all system components in a stable position.
▶
After installation, it is essential to fix the device to the floor or to the wall by
means of a wall bracket.
▶
When using a floor bracket or wall bracket, always ensure that all fastening
elements, including the wall bracket, are firmly seated.
▶
The devices must not be stacked, nor may objects be placed on top of the
devices.
▶
The device must be secured against tipping over during transport.
▶
The load must always be secured by suitable means.
▶
During transport, the respective cables must be fixed to the cable holder on
the rear.
▶
When transporting with a platform stacking truck and, in some cases, with a
hand pallet truck, the anti-tipping devices (1) may need to be removed.
▶
Is it possible to store the anti-tipping devices (1) at the rear of the device by
fixing them with butterfly nuts (2).
▶
If necessary, the anti-tipping devices (1) must be refitted in the positions
provided for them.
(1)
(1)
(2)
(2)
The device has been tested according to degree of protection IP20. This means:
-
Protection against the penetration of solid foreign bodies with a diameter of
more than 12.5 mm (0.49 in.)
-
No protection against water
The device must be set up and operated in dry, closed rooms in accordance with
degree of protection IP20. Avoid exposure to moisture.
The permissible operating position of the device is horizontal on the base.
Cooling air
The device must be set up so that cooling air can flow through the housing open-
ings provided unhindered. There must always be a minimum distance of 0.2 m
(7.874 in.) from the air inlet and outlet openings. The ambient air must be free
from
-
Excessive dust exposure
-
Electrically conductive particles (carbon black or metal chips)
-
Heat sources
The cooling air flows in and out as indicated by the arrow symbols in the follow-
ing illustrations.
17
EN-US
Содержание Selectiva 4.0 Series
Страница 1: ...Operating Instructions Selectiva 4 0 30 kW 42 0426 0359 EA 008 12052022 EN US Operating instructions...
Страница 2: ......
Страница 56: ...1 2 56...
Страница 66: ...66...
Страница 67: ...67 EN US...
Страница 68: ......