Fronius Selectiva 4.0 Series Скачать руководство пользователя страница 1

Operating

Instructions

Selectiva 4.0
30 kW

42,0426,0359,EA

008-12052022

EN-US

Operating instructions

Содержание Selectiva 4.0 Series

Страница 1: ...Operating Instructions Selectiva 4 0 30 kW 42 0426 0359 EA 008 12052022 EN US Operating instructions...

Страница 2: ......

Страница 3: ...ustomer specific information 12 Grid connection 12 Charging cables 13 Correct routing of the mains charging cables 13 Warning notices on the device 14 Warning notices inside the device 16 Setup regula...

Страница 4: ...9 Charging lights 59 Temperature controlled charging 60 Relay board 60 Aquamatic 61 Charging 61 Charge 50 61 Charge 80 61 Charge not complete 61 Charge Finish 62 Main Charge Finished 62 Cumulative Err...

Страница 5: ...Power categories General The kW specification for the power categories refers to the housing design and is not directly related to the actual device power 30 kW Selectiva 8250 8300 8375 5 EN US...

Страница 6: ...he location of the safety and danger notices on the device refer to the sec tion headed General Information in the operating instructions for the device Before switching on the device eliminate any fa...

Страница 7: ...of less than 4 is guaranteed by natural or artificial ventilation During charging observe a minimum distance of 0 5 m 19 69 in between the battery and charging system Keep potential sources of ignitio...

Страница 8: ...electrician to en sure that the ground conductor is functioning properly Safety devices that are not fully functional and components with defects must be repaired by an authorized specialist before t...

Страница 9: ...understood these Operating Instructions especially the Safety rules section and have confirmed this with their signature are trained according to the requirements for the work results The safety cons...

Страница 10: ...duce the volume of cardboard Copyright Copyright of these Operating Instructions remains with the manufacturer Text and illustrations were accurate at the time of printing Fronius reserves the right t...

Страница 11: ...ent that is really needed into the battery The technology is embedded in a sturdy industry standard housing The ex tremely compact design meets all requirements for safety standards reduces space requ...

Страница 12: ...in order for it to work Never pull on the cable when handling the device Customer spe cific information If customer specific information exists for the supplied device this is provided with the devic...

Страница 13: ...d cause a fire or explosion When charging is complete wind up the charging cables or place them on the cable holder if available Correct routing of the mains charging cables CAUTION Danger due to over...

Страница 14: ...hrend des Ladens f r ausreichend Frischluft Zufuhr sorgen Always stop charging before you disconnect the charging cable Explosive gases Prevent flames and sparks Provide adequate ventilation during c...

Страница 15: ...e battery Danger of explosion Oxyhydrogen forms in the battery during char ging Battery acid is corrosive and must never come into contact with your eyes skin or clothing Ensure there is a sufficient...

Страница 16: ...o they cannot be switched back on After opening the device use a suitable measuring instrument to check that electrically charged parts such as capacitors have been discharged With the aid of a clearl...

Страница 17: ...ng devices 1 may need to be removed Is it possible to store the anti tipping devices 1 at the rear of the device by fixing them with butterfly nuts 2 If necessary the anti tipping devices 1 must be re...

Страница 18: ...his can result in damage to property The setup of several devices one behind the other should be staggered 30 cm 11 81 in If the devices are arranged in a line one behind the other without being stagg...

Страница 19: ...er when operating the device on the pallet This can result in severe personal in jury and damage to property The device must not be operated on the pallet After installation it is essential to fix the...

Страница 20: ...9 45 mm in 950 37 4 1 1 1 Drill holes 1 according to the screws and dowels used If the surface allows it the SW10 screws 3 and washers 4 can be used which are used to store the wall brack et as shown...

Страница 21: ...itable wall using previously loosened SW10 screws 3 and washers 4 Otherwise the use of other suitable screws and washers is required 1 2 2 5 6 6 4 Push the device onto the wall so that the cable holde...

Страница 22: ...d secure it to the rear of the device using the butterfly nuts 7 for storage 8 8 2 Alternatively there is an additional storage option for the wall bracket 2 on the right side of the device It is se c...

Страница 23: ...control system option or 13 V charging lights op tion 6 USB port The USB port supports a device update and the recording of the charging parameters during the charging process via USB thumb drive A ma...

Страница 24: ...tion option Air intake with air filter 12 Connection area for options The connection area inside the device is only accessible by removing the connection plate on the front of the device To do this fo...

Страница 25: ...wire 2 Power Supply Remote Con trol wire 1 CBG Easy VCC 15 Y 3 Ext LED Yellow 16 R 4 External LED Red Remote Control wire 3 Remote Control wire 4 CBG Easy De tect 13 B Ext LED Blue 14 Dete Detect CBG...

Страница 26: ...tem or setting 5 Battery Cold indicator blue Signals a cooled down battery ready for use Lights up continuously At the end of charging the set cooling time or optionally the battery temperature has be...

Страница 27: ...but charging continues The display alternately shows the corresponding status code and the state of charge 7 Charge indicator yellow Lights up during charging Flashes when the charge has been interrup...

Страница 28: ...g of the battery charger to the electrical network 2 Use the Up Down buttons to se lect the desired menu language 3 Confirm with the Pause Start button English is set as the default language 4 Use the...

Страница 29: ...ect confirm the char ging configuration with the Pause Start button The battery charger is pre configured according to the order If the battery charger has been ordered without an additional configura...

Страница 30: ...A prompt appears asking whether the correct parameters have been set for the battery to be charged The display then appears in standard mode The display shows the battery charger parameters Type of ba...

Страница 31: ...ttons to switch between the minute counter and the standard display When the battery is fully charged all 4 bars of the battery symbol appear in black As soon as the battery is fully charged the green...

Страница 32: ...property Do not disconnect the plug connection while the charging process is running Do not touch live contacts on the charging plug NOTE Danger of battery damage when disconnecting the battery from...

Страница 33: ...2 Disconnect the charging plug When the charging contacts are open the automatic open circuit detection en sures that the charging contacts are voltage free 33 EN US...

Страница 34: ...as a battery is connected to the battery charger the charging process can only be interrupted and resumed by pressing the Pause Start button It is only possible to change the display modes with the Me...

Страница 35: ...her modes as follows 1 Press the Menu button briefly Open the desired mode 2 Use the Up Down buttons to select the symbol for the desired mode e g the battery symbol for standard mode 3 Press the Paus...

Страница 36: ...of the display window Start date of the charge e g Thursday 19 06 14 Start time of the charge e g 19 29 or charging period e g 8 h 28 min Voltage when charging starts e g 45 9 V Voltage after 5 minute...

Страница 37: ...ery Battery type e g Wet Charging characteristic e g IU Capacity Ah or charging time h depending on the charging characteristic Cells Voltage V and number of battery cells or automatic setting of the...

Страница 38: ...display of date and time as well as the software version 1 Use the Up Down buttons to call up the following information Device serial number as well as serial number and version of the config uration...

Страница 39: ...ns to make a selection e g Off On or enter a value 4 Press the Pause Start button to confirm the entry 5 If the cursor moves to the next setting or digit after confirming proceed again as described in...

Страница 40: ...the entry If one or more relevant settings for the charging process are changed in configur ation mode another prompt appears when exiting configuration mode asking whether the setting in question sho...

Страница 41: ...ion switched off Continuous Electrolyte circulation constantly switched on Program 1 to 5 Factory set programs for the electrolyte circulation and their relevant para meters can be found in the table...

Страница 42: ...the charging character istic OFF The measured battery temperature is not taken into account required Charging only starts when the temperature sensor is connected Error overtemperature ON OFF ON An er...

Страница 43: ...cification of the day of the week on which the equalizing charge is to take place The parameters for current amperes 100 ampere hours voltage volts cell and duration of the equalizing charge can be ch...

Страница 44: ...l net work is available again If the Automatic continue charging option is activated the charging process is automatically continued after a fault in the electrical network as soon as the electrical n...

Страница 45: ...ery is connected at 05 45 in the above example charging is stopped when necessary and is not interrupted by the specified end time 6 00 in the example of the set time window If the battery is connecte...

Страница 46: ...e usu al type of charge The Repeat setting defines how often the special charge is to be carried out un til charging is permanently resumed with the original charge parameters Setting range 1 to 99 re...

Страница 47: ...y charge set to ON and the battery connected the following display appears Display when RI curve is selected Display for other curves e g IUI Start opportunity charge Select the Runner symbol 1 with t...

Страница 48: ...unctions menu item A list appears with the following selection options Blue LED Setting for the time minutes after which the blue Battery Cold indicator should light up to indicate that the battery is...

Страница 49: ...of the charging cable m Cable cross section Cross section of the charging cable mm AC current consumption Adaptation of the maximum device current to the electrical installa tion on site or to the dev...

Страница 50: ...fault settings USB mode In USB mode the display shows whether a USB thumb drive is plugged in The USB thumb drive must meet the following specifications Formatting FAT32 32 Gigabyte maximum No multipl...

Страница 51: ...d for the I SPoT VIEWER on the USB thumb drive Events as well as device settings and user curves configuration are also saved The following time ranges can be selected for the data logger 1 month 3 mo...

Страница 52: ...battery The re spective error explanation can be found in the Operating Instructions for the battery If an error message appears on the display and the error cannot be rectified in dependently 1 Note...

Страница 53: ...Battery not responding 52 Battery data cannot be queried 53 Battery voltage not supported 54 Communication error 55 Battery error 56 Battery does not switch on 57 Message time limit exceeded 58 Login...

Страница 54: ...ermediate circuit 507 Primary supply voltage out of tolerance 508 Grid failure 509 Incorrect device configuration 510 Primary EEPROM faulty 527 Phaseshifter overcurrent 528 High charge relay switched...

Страница 55: ...e characteristic control 545 Primary Init failed 546 Update failed 547 Load save settings failed 548 Load save curve settings failed 549 Charge could not be continued after a power failure 550 Time no...

Страница 56: ...1 2 56...

Страница 57: ...ve the battery to be charged Always connect the compressed air output on the battery charger to the bat tery via the hose connection provided ensuring it is in perfect condition NOTE Danger due to non...

Страница 58: ...of these programs the solenoid valve picks up for an ON 1 time and drops out for an OFF 1 time This process repeats as many times as specified for Repeat After this number of repetitions has elapsed t...

Страница 59: ...increased Charging lights Suitable external indicators can be connected to the connections inside the device as shown in the figure to indicate the state of charge or the operating status of the batte...

Страница 60: ...y Do not use the relay board for safety critical functions NOTE Danger due to non compliance with the permissible mains voltage tolerance Malfunctions and damage to property may result For the relay b...

Страница 61: ...he recharging phase the solenoid valve picks up for 12 seconds then the solenoid valve drops out for 4 seconds This cycle repeats 26 times USER setting Adjustable ON time solenoid valve picks up after...

Страница 62: ...or up to 250 V AC on a grid that is grounded at the neutral point If the lamps are floating the switching current must not exceed 4 A A lamp that is controlled via the 230 V supply relay may be operat...

Страница 63: ...ired manufacturer s recommendation monthly Remote control system The remote control system allows full operation of the device from a distance of up to 30 m 98 ft 5 1 in This option contains a full co...

Страница 64: ...9 W Safety class 1 Max permitted grid impedance Zmax on PCC 3 Selectiva 8250 Selectiva 8300 Selectiva 8375 59 mOhm 51 mOhm 41 mOhm Degree of protection 4 IP 20 Overvoltage category III Operating temp...

Страница 65: ...national regulations The earth leakage current is less than 12 6 mA 3 Interface to a 230 400 V and 50 Hz public grid 4 For indoor use only must not be exposed to rain or snow 5 At a high ambient tempe...

Страница 66: ...66...

Страница 67: ...67 EN US...

Страница 68: ......

Отзывы: