Replacing the power module
Removing the
power module
1
Remove the housing (see chapter
)
2
Remove the mains cable and the
device frame (see chapter
3
Remove the fan including the fan
holder (see chapter
1
2
1
1
Remove the two M5x10 TX25 screws
for the charging leads.
2
Remove the M5x10 TX25 screw on
the EMC plate.
1
NOTE!
Possible damage to the device due to
defective soldering points.
▶
When removing or inserting the power
module, only grasp the heat sink to
move it.
1
Push the power module out toward the
AC side or pull it out.
35
EN
Содержание Selectiva 2040