Calibrating the
empty state
20 mm (0.79 in.)
1
Drain the parting agent container until
the parting agent level is at least 20
mm (0.787 in.) below the sensor
2
Establish a power supply to the sensor
2 - 6 s
3
Press the "OUT OFF" button for
between 2 and 6 seconds
-
The LED on the sensor flashes
slowly
-
After releasing the "OUT OFF"
button the LED goes out - the
sensor has detected a low fluid
level
Calibrating the
full state
1
Fill the parting agent container with
parting agent
> 6 s
2
Press the "OUT OFF" button for at
least 6 seconds
-
The sensor LED flashes slowly at
first, then more rapidly after 6
seconds
-
After releasing the "OUT OFF"
button the LED goes out - the
sensor has detected a high fluid
level
63
EN
Содержание Robacta Reamer V
Страница 2: ......
Страница 12: ...12 ...
Страница 13: ...General 13 ...
Страница 14: ...14 ...
Страница 18: ...Notice warning of automatic start up of the device 18 ...
Страница 22: ...Mounting plates for the wire cutter including fixings 22 ...
Страница 24: ...24 ...
Страница 25: ...Controls connections and mechan ical components 25 ...
Страница 26: ...26 ...
Страница 34: ...34 ...
Страница 35: ...Installation and commissioning 35 ...
Страница 36: ...36 ...
Страница 43: ...Attach the spatter tray retainer as shown 3 43 EN ...
Страница 45: ...7 45 EN ...
Страница 55: ...1 3 2 1 4 NOTE The wire cutter must be controlled elec trically by the robot control 55 EN ...
Страница 60: ...1 Finely adjusting the spray amount on parting agent adjuster 60 ...
Страница 83: ...Care maintenance and disposal 83 ...
Страница 84: ...84 ...
Страница 86: ...Disposal Dispose of in accordance with applicable national and local regulations 86 ...
Страница 87: ...Troubleshooting 87 ...
Страница 88: ...88 ...
Страница 93: ...Technical data 93 ...
Страница 94: ...94 ...
Страница 97: ...Appendix 97 ...
Страница 98: ...Circuit diagram Robacta Reamer V 98 ...
Страница 101: ...Robacta Reamer V pneumatic diagram 101 ...