5
EN
Before Initial Operation
Intended Use
Set-up require-
ments
Mains supply
The MC fume extractor must only be used for the removal of acidic vapours that arise
during electro-chemical cleaning of high-alloy steels.
The MC fume extractor must only be operated in conjunction with the MagicCleaner
CrNi cleaning device.
Any other form of use is seen as not the purpose for which the machine was intended.
The manufacturer will not be liable for damage arising from such improper use.
Intended use also comprises
-
Following all information given in this manual
-
Following all information given in the manual for the MagicCleaner CrNi-Cleaning
Device
-
Performing all stipulated inspection and maintenance work
The MC fume extractor is tested to IP23, meaning:
-
Protection from penetration by solid foreign bodies larger than Ø 12 mm
-
Protection from water spray up to an angle of 60° to the vertical
In accordance with IP23 the MC fume extractor can be set up and operated outdoors.
The electrical parts fitted must be protected from direct moisture.
Important!
Place the cleaning / extraction system on an even and firm floor in such a
way that it stands firmly.
Air must be able to circulate freely around the air channels or air slots for turbine ex-
haust air. Any electroconductive metallic dust (e.g. from grinding work) must not be
allowed to be sucked into the machine.
The operating temperature and storage temperature for the cleaning/extraction system
must not drop below -10°C. Set up the cleaning/extraction system so that additional
heating due to heat sources such as radiators, heating or annealing furnaces, direct
insulation etc. is avoided.
The MC fume extractor is designed for the supply voltage given on the rating plate. If
the mains cable or mains plug are not fitted on your equipment model, then they must
be fitted in accordance with national standards. The technical specification provides
information regarding fuse protection for the mains cable.
Note!
Inadequately dimensioned electrical installations can lead to serious
damage to property. The mains plug, mains supply lead, as well as their fuse
protection, must always be designed accordingly.
Any electrical intervention, including fitting or removal of the mains plug may only be
carried out by a qualified electrician.