Measures to Reduce Contamination of the Optics
Measures to
Reduce Contam-
ination of the
Optics
Crossjet and Extraction
1.
Please observe the values for the crossjet and extraction specified in these Operat-
ing Instructions.
2.
Switch on the crossjet and extraction at least five seconds before the start of weld-
ing.
3.
Do not switch off the crossjet and extraction until the laser welding head is safely in
the smoke-free zone.
Protective Glass (including Replacement)
IMPORTANT!
Before changing the protective glass drawer, clean the area around it with
a cleaning cloth.
The environment must be clean when the protective glass drawer is being replaced.
4.
To prevent dust from penetrating the focusing lens, the laser welding head must be
vertical when the protective glass is being changed (welding torch pointing toward
the floor).
5.
Before changing the protective glass:
5.
Switch on the extraction and crossjet
5.
Clean the welding head with compressed air as best as you can
IMPORTANT
Do not blast the protective glass with the air current directly.
5.
Switch off crossjet
5.
Replace protective glass
IMPORTANT
When replacing the protective glass, the extraction must be
switched on and crossjet switched off.
6.
Keep the amount of time the protective glass drawer is open to the minimum neces-
sary.
7.
If there are welding fumes on the protective glass, replace the protective glass with a
new pane of glass.
The contaminated protective glass can be used again:
7.
Pre-clean the protective glass with a cloth
7.
Finish cleaning the protective glass with a cotton swab soaked in methanol
7.
Store the protective glass in a dust-free area
8.
If there is welding spatter on the protective glass, the protective glass must be
replaced with a new pane of glass immediately.
Dispose of the protective glass that has welding spatter.
9.
Check the protective glass from time to time at the start of production in order to
determine a change interval specific to the application.
Automated Torch Cleaning Device
10. When using an automatic torch cleaning device:
Switch on the crossjet and extraction during the cleaning process.
95
EN-US
Содержание LaserHybrid SB 360i
Страница 2: ......
Страница 14: ...14 ...
Страница 15: ...General information 15 ...
Страница 16: ...16 ...
Страница 30: ...30 ...
Страница 31: ...Operating controls and connections 31 ...
Страница 32: ...32 ...
Страница 40: ...40 ...
Страница 41: ...Commissioning 41 ...
Страница 42: ...42 ...
Страница 53: ...8 8 9 Pull protective hoses over the connec tions 53 EN US ...
Страница 57: ...7 8 Torx 40 1 Nm 0 74 lb ft 9 10 2 1 11 12 57 EN US ...
Страница 59: ...7 8 12 mm 5 Nm 3 69 lb ft 42 0411 0160 2 9 10 2 1 11 12 59 EN US ...
Страница 68: ...68 ...
Страница 83: ...Maintenance 83 ...
Страница 84: ...84 ...
Страница 97: ...Appendix 97 ...
Страница 98: ...98 ...
Страница 102: ...102 ...
Страница 103: ...103 EN US ...