NOTE!
The "VALVE ON" signal for controlling the solenoid valve (2) is transmitted on bit
26 (away from 0).
Pressure monit-
oring in the Split-
Box SB 360i
LaserHybrid
The pressure is measured after the solenoid valve.
If the pressure falls below 4.5 bar for longer than 2 seconds, then the "Powersource
Ready" bit is withdrawn and the warning code 16835 (laser Crossjet air pressure supply
low) is output.
From power source software version 2.4.0:
If the pressure drops below 4.5 bar for longer than 2 seconds, the "Warning-Bit" is set
and the error code 16835 (laser Crossjet air pressure supply low) is output.
The current Crossjet pressure is displayed in the SmartManager (power source website)
under "Actual system data".
39
EN-US