66
Yield
Setting
-
of an OFFSET value for the total energy display
-
of a measuring offset factor for the day, year and total energy display
Meter deviation
Input of a value for the fed-in energy that will be added to the energy currently fed in (e.g.
carry-over value when replacing an inverter)
Meter unit of measurement
Input of a unit (k..., M...)
Meter calibration
Input of a correction value to ensure that the value shown on the inverter display corre-
sponds with the calibrated display on the electricity meter
DATCOM
Checking data communications, entering the inverter number, protocol settings
Status
Indicates data communication is taking place via a Fronius Solar Net or that a data com-
munications error has occurred
Inverter number
Sets the number (= address) of the inverter in a system with several solar inverters
Setting range
Meter deviation / meter unit of measurement / meter calibration
Unit
Wh
Setting range
Five digits
Factory setting
0
Unit
-
Setting range
k / M
Factory setting
-
Unit
%
Setting range
-5.0 - +5.0
Factory setting
0
Setting range
Status / inverter number / protocol type
Unit
-
Setting range
00 - 99 (00 = 100th inverter)
Factory setting
01
IMPORTANT!
If a number of inverters are linked together in a data communications sys-
tem, assign a unique address to each one.