53
EN-US
Connecting Solar Module Strings to the Fronius DC
Box 60/12
Safety
Notes for Con-
necting Solar
Module Strings to
the
Fronius DC Box
60/12
Recommended sequence for inserting and connecting DC cables
Terminal assign-
ment for ground-
ed solar modules
For grounded solar modules, only the ungrounded poles of the solar module strings may
be connected to the fuse-protected terminals (A).
WARNING!
An electric shock can be fatal. Danger from DC voltage from solar
modules.
-
Make sure that the input and output sides in front of the device are not
charged before connecting anything.
-
Any and all connections should only be carried out by qualified electricians.
-
Follow the safety rules in these operating instructions.
NOTE!
Only use a DC cable with the correct polarity at
the terminals for DC cable 'IN' and at the terminals with
fuse holders for DC cable 'IN'.
NOTE!
To ensure problem-free DC cable connections to the terminals, the length
of the DC cables should be no less than 330 mm (measured from the inside bot-
tom edge of the Fronius DC Box 60/12).
NOTE!
Observe the sequence when inserting and connecting DC cables: from
bottom to top and from the inside outwards.
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
Negative solar module ground
DC-
DC+
B (in)
B‘ (out) A‘ (out)
A (in)
Positive solar module ground
DC+
DC-
B (in)
B‘ (out) A‘ (out)
A (in)