19
EN-US
Sensor Card / Box
Com Card
Sensor Card / Box
Supply voltage
12 V DC
Power consumption
- Sensor card:
- Sensor box:
1.1 W
1.3 W
Box degree of protection
IP 20
Dimensions (l x w x h)
- Sensor card:
- Sensor box:
140 x 100 x 26 mm
197 x 110 x 57 mm
Interfaces
(only sensor box)
Socket:
Description:
- RS 422:
RJ 45
„IN“
- RS 422:
RJ 45
„OUT“
Channels T1, T2
- Sensors:
PT1000
- Measuring range:
-25°C...75°C; -13°F...167°F
- Accuracy:
0,5°C; 0,8°F
- Resolution:
1 °C; 1 °F
Irradiance channel
- Measuring range:
0...100 mV
0...200 mV
0...1 V
- Accuracy:
3 %
Channels D1, D2
- Max. voltage level
5.5 V
- Max. frequency
2500 Hz
- Min. pulse duration
250 us
- Switching threshold „OFF“ („LOW“):
0...0.5 V
- Switching threshold „ON“ („HIGH“):
3...5.5 V
Current input channel
- Measuring range:
0...20 mA
4...20 mA
- Accuracy:
5%
Com card up to version 1.4B (4,070,769)
Supply voltage
230 V (+10% / -15%)
Dimensions (l x w x h)
- Plug-in card only:
140 x 100 x 33 mm
Interfaces
Socket:
Description:
- RS 422:
RJ 45
„IN“
- RS 422:
RJ 45
„OUT“
Содержание DATCOM Compact
Страница 2: ...2...
Страница 4: ...4...
Страница 22: ...22...
Страница 24: ...24...
Страница 42: ...42...
Страница 44: ...44...
Страница 62: ...62...
Страница 64: ...64...
Страница 65: ...65 RU DATCOM Fronius DATCOM CD www fronius com Fronius DATCOM...
Страница 66: ...66 Fronius DATCOM DATCOM Fronius DATCOM Fronius...
Страница 70: ...70 1 2 Sensor Card DATCOM 3 4 5 IN 6 OUT DATCOM Datalogger pro Box 5 6 DATCOM 1 2 3 4 5 6...
Страница 78: ...78 Fronius 5...
Страница 84: ...84 Fronius Fronius www fronius com solar warranty Fronius www solarweb com...
Страница 85: ...85 RU...