12
Notes on the relay contacts and on the monitoring
and protection contacts
Overview
Relay Contacts, Monitoring & Protection
Cable cross-section: 0.14 - 4 mm²
Tightening torque of terminals: 0.5 Nm
Max. continuous current: 16 A
Min. switching load: 500 mW (10 V / 5 mA)
Switching capacity: 16 A / 250 V (AC1) and 16 A / 30 V (DC1)
(1)
Relay contacts
NC1
NC for relay contact 1
SC1
Relay contact 1
NO1
NO for relay contact 1
NC2
NC for relay contact 2
SC2
Relay contact 2
NO2
NO for relay contact 2
The relay outputs are not fuse-protected.
Relay contacts can be assigned different functions in the Basic service menu.
The access code 22742 must be entered to access the Basic service menu:
-
Press the 'Menu' key
-
Select 'Setup' mode
-
Press the unassigned 'Esc' button five times
-
Enter the access code 22742
-
Select the 'Switch contact 1' or 'Switch contact 2' parameter
-
Set the desired relay contact function
(1)
(2)
(3)
(4)
(1) - (4) ... 0,5 Nm
*
*