1-10
1.4.3 Battery test
The battery should be checked while each maintenance with a battery tester.
Information to the Battery tester you will get by FROMM System GmbH.
(see 1.10 SERVICE ADDRESS)
•
Li-Ion-Batteries 36V / (2,5Ah) must be replaced at a capacity less than approx. 73% (1,83 Ah).
•
Li-Ion-Batteries 36V / (4,0Ah) must be replaced at a capacity less than approx. 60% (2,4 Ah)
1.4.4 Checklist
Carry out some test strappings and check following tool components.
•
Inserting of the strap
•
Insert battery in the tool and check function of the LED-display (see operation manual P331)
•
Strap feed and strap tension
•
Tension force adjustment (see operation manual P331)
•
Cutting of the upper strap
•
Welding time adjustment (see operation manual P331)
•
Seal quality (see operation manual P331)
•
Function of the LED-display (see operation manual P331)
•
Correct type label
1.4.5 Lubrication rules
All gear parts have to be lubricated with
MOLYKOTE BR2 PLUS
grease.
Lubrication interval: While each maintenance or after 12 months at the latest.
All bearing parts of the welding unit have to be cleaned and lubricated as follows:
All other parts have to be lubricated according to the explosion drawing.
Lubrication interval: While each maintenance or after 12 months at the latest.
P32.1029
N3.1702 (6X)
P32.1027
P35.4107
P35.4210
Mobilux EP2
Klüber Isoflex Alltime SL2
Klüber Isoflex NBU 15
P35.4111
P35.4111
grease here
P35.4106