ERRORS DURING OPERATION
THE MACHINE DOESN’T STOP WHEN THE EMERGENCY MUSHROOM-HEAD BUTTON IS
PRESSED
Problem suggestion
Possible solution
- Emergency circuit failure
- Check the circuit
- Reset not working
- Check if there are other errors or failures
preventing an correct reset. (
Fig. 2)
- Emergency mushroom-head button not
working
- Replace the emergency mushroom-head button.
(
Fig. 1
)
- Check LED L23 (1) (
Fig. 3)
(If not pressed LED is ON after pressing the
RESET button (
Fig. 2
)
Fig. 1
Fig. 2
Fig. 3
Should the problem persist, contact the Customer After-Sales Service of MANUFACTURER
THE TURNS AT THE BOTTOM AND AT THE TOP OF THE LOAD ARE NOT REGULATED
PROPERLY
Problem suggestion
Possible solution
- Proximity sensor (
Fig. 1
) not connected
properly
- Check the wiring
- Check the LED L27 (6) (
Fig. 3
)
With turntable in ZERO the light is ON
- Move the turntable in JOG function.
LED L27 should flash 3x during one round.
- Proximity sensor
doesn’t give a signal
- The distance sensor (1) bracket (2) has to be
approx 3 to max 6mm (3). (
Afb. 1
)
- Shaft rotating bracket (
Fig. 2
) not
connected properly
- Fixed the bracket in the correct position (4) (
Fig. 2
)
- Proximity sensor malfunction
- Replace the proximity sensor. (5) (
Fig. 2
)
- Control card (
Fig. 3
) not working
properly
- Replace the faulty card (
Fig. 3
) by carefully
referring to the wiring diagram attached to the
machine documentation.