Technology
Components, Connections, and Dimensions
Fröling Heizkessel- und Behälterbau Ges.m.b.H, Industriestrasse 12, A-4710 Grieskirchen
Page 15
Tel +43 (0) 7248 606-0 Fax +43 (0) 7248 606-600 [email protected] www.froeling.com
M0930408_en
2
2.3.2
P4 Pellet 32/38/48/60
P4 Pellet
Component
Unit
32
38
48
60
Rated heat output
32,0
38,0
48,0
58,5
Heating efficiency range
kW
8,9-32,0 8,9-38,0 14,4-48 17,3-58,5
Mains connection
230V / 50Hz fused 16A
Output
W
110 110 120 120
Weight of boiler
kg
530
530
760
760
Boiler capacity (water)
l
125
125
170
170
Upstream resistance (
Δ
T=20°C)
mbar
1,5 2,1 3,6 5,3
Minimum return feed temperature
Not applicable because of internal return feed lift
Maximum boiler temperature setting
80
80
80
80
Minimum boiler temperature setting
°C
40 40 40 40
Permitted operating pressure
bar
3
3
3
3
Boiler
class
3 3 3 3
Permitted fuel
Wood pellets Ø 6mm as per ÖNORM M 7135 / DIN
51731
Test report data
Testing institute
TÜV SÜD SZA
1)
3) 4)
TÜV
2)
Test report no.
K44302/6
K44302/4
-
08-UWC/
Wels-EX-
337
Test data at rated load
Carbon monoxide (CO)
[mg/MJ]
31
45
25
5
Nitrogen oxide (NOx)
[mg/MJ]
79
77
77
77
Organic
hydrocarbons
[mg/MJ]
1,0 1,0 1,5 <
2
Dust [mg/MJ]
10
9
10
11
Boiler efficiency rating
[%]
93,5
92,6
92,4
92,1
Prüfdaten bei Teillast
Carbon monoxide (CO)
[mg/MJ]
61
61
36
10
Nitrogen oxide (NOx)
[mg/MJ]
75
75
71
66
Organic
hydrocarbons
[mg/MJ]
1,0 1,0 1,5 <
2
Dust
[mg/MJ]
10 10 10 10
Boiler efficiency rating
[%]
95,7
95,7
94,0
92,3
1) TÜV Austria, Environment and Chemistry Division, Am Thalbach 15, A-4600 Thalheim/Wels
2) In accordance with ÖNORM / DIN EN 303-5, chapter 5.1.3 type test: for a boiler from a range with a consistent
structure it is sufficient, if the ratio of rated heat output from the largest to the smallest boiler
≤
2 : 1, to carry out the
tests with the smallest and the largest boilers. The boiler manufacturer must ensure that all boilers, including those that
have not been tested in a range, whose values have been determined depending on rated heat output by interpolation,
fulfil the requirements of the norm.
3) Values of the type P4 Pellet 20 are interpolated between the test protocol 06-UWC/Wels-EX-295/1 and K44302/2.
5) Values of the type P4 Pellet 25 are interpolated between the test protocol 06-UWC/Wels-EX-295/1 and K44302/2.