Lubricate the stoker bearings [~1000 B/every six months]
FET
T
3x
❒ Lubricate stoker bearings with three grease gun strokes per grease nipple
Check chain and sprockets [~1,000 operating hours / every six month]
Kettenspanner nicht einstellbar!! (prl, 10.07.2020)
❒ Loosen the screw at the top of the cover and remove the cover by pulling it
downwards
❒ Check chain and sprockets for wear, replace if necessary
❒ Grease chain and sprockets using suitable lubricant
❒ Check chain for tension
Clean the combustion chamber [~2500 Bh /yearly]
❒ Open the insulated door
❒ Pull out the ash container
❒ Open the combustion chamber door by turning the Allen wrench (90°)
➥ Use the Allen wrench included (A – AF 13 mm)
➥ Allen wrench stored in tool clip (B)
5
Servicing the system
Maintenance work by the operator
56
Froling GesmbH | A-4710 Grieskirchen, Industriestraße 12 | www.froeling.com