4 | Operating the system
28
B1650222_en | Operating instructions PE1e Pellet
4.3.3 Switch boiler ON/OFF
The hydraulic system is controlled in accordance with the mode that is set, regardless of
boiler status,
Boiler ON
The boiler is activated and starts following a command from the
hydraulic system. (Storage tank, heating circuit, domestic hot
water…). Heating circuits and domestic hot water tanks are
controlled according to the programs and times set.
Boiler OFF
The control follows the boiler shutdown procedure and starts the
cleaning cycle. The boiler switches to “Boiler OFF” status. All
boiler units are deactivated, heating circuits and domestic hot
water tanks are controlled according to the programs and times
set, the chamber discharge system remains active.
4.3.4 Change boiler mode
Depending on the type of boiler, there are several modes
available which can be changed directly in the basic
display of the touch display.
Mode
Icon
Description
Automatic
Supply heating circuits and domestic hot water tanks with
heat according to the selected heating times.
Domestic hot water
The domestic hot water tank is supplied with heat within
the selected loading times. Heating circuits are switched
off, frost protection remains active.
Continuous load
The boiler continuously maintains the selected boiler
temperature setpoint and only shuts down for cleaning
purposes. Supply heating circuits and domestic hot water
tanks with heat according to the selected heating times.
NOTICE! Consult the enclosed operating instructions for the boiler controller for a
detailed description of the boiler modes.