4.3.10 Change room temperature (heating circuit without room temperature sensor)
Situation
Effect
Room temperature generally too low
Move heating curve up in parallel.
Increase both points on the heating curve by
the same temperature level. (see figure 1)
Room temperature on cold days too low, OK
on warm days
Change the slope of the heating curve.
Increase the temperature level of the heating
curve at -10°C outside temperature
(see figure 2)
Room temperature on warm days too high,
OK on cold days
Change the slope of the heating curve.
Reduce the temperature level of the heating
curve at +10 °C outside temperature
(see figure 3)
Figure 1
Figure 2
Figure 3
Depending on the situation, the heating curve an be adapted by tapping “+” or “-” at
+/-10°C outside air temperature.
If the heating curve is to be changed, never change the desired point for a high
temperature circuit more than 5°C, and never more than 3°C for a low temperature
circuit. Once the changes have been made, wait a few days and assess comfort levels
before carrying out additional changes.
Operating the system
4
Operate the boiler using the touch display
Operating Instructions PE1 Pellet 7-35 / PE1 Pellet Unit 7-20 | B1001020_en
35