Fröling Lambdatronic S 3100 Скачать руководство пользователя страница 22

Control Sy

stem  

Lamb

datro

nic S 3100 

 

SERVICE INSTRUCTIONS 

 

FRÖLING Heizk

essel und Be

hälterbau

 GmbH 

 

B 018 10 04 

A-4710 Grieskirchen, Industriestr

aße 12, 

Tel.: +43 (0)724

8/606-0

  

Page 15 of 

24

 

 

6.9 Setting  parameters 

You must check and if nec

essa

ry a

dju

st the parameters bel

ow

 

 

Heating

 curv

e: 

radiator or un

derfloor he

ating 

 

Minimu

m flue 

gas temp

erat

ure: 

increase va

lue for chimneys 

with

out ceramic or stainless steel pipe. 

 

Targe

t re

sidua

l O2 c

onten

t: 

this setting shoul

d be adjuste

d to the fuel.  

Recommend

ed: bet

ween 

8...10% (in exc

eptiona

l cases 7...11%) of residu

al O2 content.

 

 

 

The other para

meters are factor

y set i

n such 

a w

ay that in m

ost cases optimal

 operatio

n is possib

le 

with

out further 

parameterisati

on. 

 

The follo

win

g p

arameters, ho

wever, can/sh

ould b

e ad

justed as desire

d b

y the customer: 

 

 

Targ

et bo

iler temper

ature 8

 (hit ENTE

R

 three times)

 

 

Storage tank... 

 

DHW... 

 

Solar... 

 

Reduction prog

rams... 

 

Heating circuits 1 – 4... 

 

6.10 Measuring  emissions 

 

If you do n

ot h

ave a Lam

bda control, 

you w

ill nee

d to set the secondar

y air b

y w

ay 

of an emission 

measurement 

using the “Sec.

air MA

X“ parameter in the air settings. 

 

If you hav

e a Lambd

a control 

it is recommended 

you carr

y out an emiss

ion

s measureme

nt as a gen

eral 

check. 

 

When starting 

up for the first time, the emissions meas

urement shou

ld onl

y be carrie

d out 

after approx. tw

hours' he

ating time, at a stead

y glo

w a

nd w

hen 

the boil

er temperature is at least 65°C. 

 

You have no

w compl

eted al

l the steps req

uir

ed for start up.  

Initial start up is no

w comp

lete

 

 

 

7 Troubleshooting 

How

 to procee

d w

he

n a fault 

occurs: 

 

1. 

Find an

d elimin

ate the fault. 

2. 

Acknow

led

ge the fault b

y pr

essing Enter. 

3. 

If the system d

oes not start up again a

utom

atica

lly 

after yo

u have ackn

owled

ged the faul

t, press start 

button I. 

 

General  fault in po

wer sup

ply

 area: 

 

Error 

Cause 

Eliminatio

n of error 

No disp

lay,

 no

 pow

er 

on 

control 

FI protective circuit break

er or line 

protection is switched off 

Sw

itch

 back on 

 

Main sw

itch

 is off 

Sw

itch

 on 

 

Glass tube fusing for control 

blo

wn 

Replace fus

e –

 note current: 10 A 

 

 

NOTE for heat

ing up

:  

if the ID fan does not conti

nue to run 

when 

you close the in

sulating d

oor, press the gree

start button. 

Содержание Lambdatronic S 3100

Страница 1: ...NG 4 PUMPE 1 PUMPE 2 PUMPE 3 GEBL SE EINGABE 0 A HEIZUNG 1 PUMPE HZG 0 L GEBL SE 2 3 4 1 2 3 2 3 4 5 6 7 8 9 1 1 Two line display 2 Menu buttons 3 Button Start Stop 4 Status LED 5 Operating display fo...

Страница 2: ...e instructions and advice could cause damage to the appliance and personal injury Main switch RISK Never stop the boiler using the main switch Do not stop burn off The main switch may only be activate...

Страница 3: ...ments The system is operated using a 4 button control unit with a clear menu structure All of the parameters necessary for operation are at the customer s disposal ZUR C ZUR CK EINGABE Feuer Aus Kesse...

Страница 4: ...er value The value can now be changed 4 Change the value The up arrow key increases the value The down arrow key decreases the value Changing parameters and values 5 Confirm with the Enter key EINGABE...

Страница 5: ...child lock or 1 for customer confirm by pressing Enter If you enter the wrong code the code for child lock will automatically be used User code The name of the set user level will appear briefly Off...

Страница 6: ...prog 1 Enter Back Heating phase1 start Heating phase1 end Heating phase2 start Heating phase2 end Heating prog 2 Heating prog 14 same as heating prog 1 Heating circuit 1 Enter Back Heating curve Ente...

Страница 7: ...en the set temperature is reached in the DHW the DHW loading pump switches off Set DHW temp 2 55 When the set temperature is reached in the DHW the DHW loading pump 2 switches off Reload if boiler und...

Страница 8: ...ue during the drawdown phase is only visible with remote control Flow temperature reduction 15 The flow temp is reduced by this value in the drawdown phase Ex temp heating limit 18 If the outside temp...

Страница 9: ...limination of the error has been acknowledged by pressing the ENTER key the status LED returns to green Chapter 7 2 Error message list contains a list of possible error messages 7 Troubleshooting What...

Страница 10: ...per closed On actuator swap connection for left with right Check dampers can turn Check cable and connection Storage temp low RELOAD W Top storage tank temperature insufficient for heat supply Info on...

Страница 11: ...heating times here Heating phase 1 Heating phase 2 Heating phase 1 Heating phase 2 Start End Start End Start End Start End Heating prog 1 Heating prog 8 Heating prog 2 Heating prog 9 Heating prog 3 He...

Страница 12: ...g session 14 00 End of the second loading session 16 00 Heat only once day N Legionella heating65 Y Legionella heating day Sat Solar Set hot water temp 55 Heating circuit 1 Flow temp at outer 10 C 60...

Страница 13: ...Lambdatronic S 3100 Control System SERVICE INSTRUCTIONS B 018 10 04 FR LING Heizkessel und Beh lterbau GmbH Page 24 of 24 A 4710 Grieskirchen Industriestra e 12 Tel 43 0 7248 606 0 Notes...

Страница 14: ...bdatronic S 3100 SERVICE INSTRUCTIONS FR LING Heizkessel und Beh lterbau GmbH B 018 10 04 A 4710 Grieskirchen Industriestra e 12 Tel 43 0 7248 606 0 Page 23 of 24 10 List of parameter changes Paramete...

Страница 15: ...ng circuit pump 0 or as an oil boiler contact depending on the system settings Connecting a HCP 0 up to 2 Ampere Connecting a HCP 0 up to 5 Ampere External feed Connection as an oil boiler contact NOT...

Страница 16: ...not be longer than 20 m Console RBG 3100 also includes a room sensor which sends the current room temperature to the control Note RXD and TXD must be crossed over RXD on TXD TXD on RXD 9 10 PC Visuali...

Страница 17: ...6 pin 9 7 Flue gas sensor 9 8 Remote control The remote control also contains a room sensor which sends the current room temperature to the control Switch settings Override circuit ignores the reduct...

Страница 18: ...eating circuit pump 9 4 Jumper setting for actuators The jumpers on the motherboard 3100 must be adjusted to the type of actuator in the air dampers Actuator Jumpers on motherboard 3100 without feedba...

Страница 19: ...RC 3 Remote control 3 RC 4 Remote control 4 FS 3 Flow sensor 3 FS 1 Flow sensor 1 ES 1 External sensor 1 FS 2 Flow sensor 2 RC 1 1 Remote control RC 2 Remote control 2 Mixer 3 Mixer 1 Mixer 4 Mixer 2...

Страница 20: ...or 3 Sensor 2 Sensor 1 Sensor 4 Sensor 5 HCP 0 N PE1 PE2 A W H A A HCP oil Lambda board 3100 optional View of bottom level Control element 3100 Flat ribbon cable to expansion board 1 Flat ribbon cable...

Страница 21: ...onnection for left with right Check dampers can turn Check cable and connection Storage temp low RELOAD W Upper storage tank temperature insufficient for heat supply Info only no error automatic ackno...

Страница 22: ...will need to set the secondary air by way of an emission measurement using the Sec air MAX parameter in the air settings If you have a Lambda control it is recommended you carry out an emissions measu...

Страница 23: ...hecking the door sensor switch Door sensor A 0 door closed switch activated A 1 door open switch not activated If the insulating door is open the ID fan will start up 6 7 Checking the tightness and sy...

Страница 24: ...Press the Enter button A question mark will appear Now enter the code for the Installer or Service user level Confirm by pressing Enter If you enter the wrong code the code for child lock will automat...

Страница 25: ...Please note that heating circuits 1 and 3 can be used for solar element 5 8 2 System parameters The actual number of parameters of those listed below depends on the system settings Bypass pump av Yes...

Страница 26: ...bda probe is available FHG Turbo 30 FHG Turbo 40 Comb chamb sensor av N Y if a combustion chamber sensor is available FHG Turbo 50 FHG Turbo 70 Actuator with feedback N Y Actuators with feedback have...

Страница 27: ...PEN A 0 Primary air damper OPEN Prim fl CLOSED A 0 Primary air damper CLOSED Sec fl OPEN A 0 Secondary air damper OPEN Sec fl CLOSED A 0 Secondary air damper CLOSED A 0 Automatic OFF A AUTOMATIC A 1 A...

Страница 28: ...pressing the ENTER key Short red flashes Warning or error persists not acknowledged Long red flashes Warning or error persists but acknowledged Warning The status LED automatically changes to green as...

Страница 29: ...e flue gas temperature Top load point to ensure adequate efficiency if this temperature is exceeded the output will be reduced Flue gas temp start add 20 Flue gas target value increase when heating up...

Страница 30: ...each like heating prog 1 You can program up to 14 heating times each with two heating phases These are assigned to the individual days of the week in the parameter Heating circuit 1 4 weekly program...

Страница 31: ...switched off Oil boiler Oil boiler storage temp diff 10 The minimum temperature difference between the oil boiler and storage tank which releases the oil boiler loading pump output Oil boiler start d...

Страница 32: ...rage temp diff 10 Temperature difference for launching storage tank loading process Residual heat use N This function can only be used in conjunction with a bypass pump return feed mixer The residual...

Страница 33: ...iler temperature is exceeded by a set value the status of the boiler will be maintained glow Once the temperature goes back down below the target boiler value the boiler s status will return to heatin...

Страница 34: ...100 Mixer Ty 240s ID fan 36 Solar Primary air 76 ERROR DISPLAY Heating times Prim damp pos 77 Heating circuit 1 O2 content 7 9 Heating circuit 2 O2 controller 78 Heating circuit 3 Sec air 77 Sec damp...

Страница 35: ...ontrol 17 9 Connection instructions 19 9 2 Mains connection 19 9 3 Heating circuit pumps for underfloor or wall heating 19 9 4 Jumper setting for actuators 19 9 5 Jumper setting for solar control 19 9...

Страница 36: ...UMPE 2 PUMPE 3 GEBL SE EINGABE 0 A HEIZUNG 1 PUMPE HZG 0 L GEBL SE 2 3 4 1 2 3 1 Two line display 2 Menu buttons 3 Button Start Stop 4 Status LED 5 Operating display for pumps 6 Fan 7 Switch heater 0...