SERVICE INSTRUCTIONS
FRÖLING Heizk
essel und Be
hälterbau
GmbH
B 018 10 04
A-4710 Grieskirchen, Industriestr
aße 12,
Tel.: +43 (0)724
8/606-0
Page 15 of
24
6.9 Setting parameters
You must check and if nec
essa
ry a
dju
st the parameters bel
ow
:
•
Heating
curv
e:
radiator or un
derfloor he
ating
•
Minimu
m flue
gas temp
erat
ure:
increase va
lue for chimneys
with
out ceramic or stainless steel pipe.
•
Targe
t re
sidua
l O2 c
onten
t:
this setting shoul
d be adjuste
d to the fuel.
Recommend
ed: bet
ween
8...10% (in exc
eptiona
l cases 7...11%) of residu
al O2 content.
The other para
meters are factor
y set i
n such
a w
ay that in m
ost cases optimal
operatio
n is possib
le
with
out further
parameterisati
on.
The follo
win
g p
arameters, ho
wever, can/sh
ould b
e ad
justed as desire
d b
y the customer:
•
Targ
et bo
iler temper
ature 8
0°
←
(hit ENTE
R
three times)
•
Storage tank...
•
DHW...
•
Solar...
•
Reduction prog
rams...
•
Heating circuits 1 – 4...
6.10 Measuring emissions
⇒
If you do n
ot h
ave a Lam
bda control,
you w
ill nee
d to set the secondar
y air b
y w
ay
of an emission
measurement
using the “Sec.
air MA
X“ parameter in the air settings.
⇒
If you hav
e a Lambd
a control
it is recommended
you carr
y out an emiss
ion
s measureme
nt as a gen
eral
check.
⇒
When starting
up for the first time, the emissions meas
urement shou
ld onl
y be carrie
d out
after approx. tw
o
hours' he
ating time, at a stead
y glo
w a
nd w
hen
the boil
er temperature is at least 65°C.
You have no
w compl
eted al
l the steps req
uir
ed for start up.
Initial start up is no
w comp
lete
.
7 Troubleshooting
How
to procee
d w
he
n a fault
occurs:
1.
Find an
d elimin
ate the fault.
2.
Acknow
led
ge the fault b
y pr
essing Enter.
3.
If the system d
oes not start up again a
utom
atica
lly
after yo
u have ackn
owled
ged the faul
t, press start
button I.
General fault in po
wer sup
ply
area:
Error
Cause
Eliminatio
n of error
No disp
lay,
no
pow
er
on
control
FI protective circuit break
er or line
protection is switched off
Sw
itch
back on
Main sw
itch
is off
Sw
itch
on
Glass tube fusing for control
blo
wn
Replace fus
e –
note current: 10 A
NOTE for heat
ing up
:
if the ID fan does not conti
nue to run
when
you close the in
sulating d
oor, press the gree
n
start button.