FBM-FOBBLES-F8-PRO User Manual
- 11 -
Channel
Function
Value
Description
1
Bubble Output
0-10
OFF
11-255
ON
2
Fog Output
0-10
OFF
11-255
Fog volume, low to high
3
Fan Output
0-10
OFF
11-255
Fan speed, low to high
4
Bubble Cleaning Mode
0-10
OFF
11-255
When Bubble cleaning mode is ON, overriding other
functions
6
TECHNICAL INFORMATION
6.1
Maintenance
Do not allow the FOBBLES F8 PRO to become clogged due to residue buildup of bubble and fog fluid. Cleaning and preventative
maintenance are necessary to keep your machine running issue free. Please follow these instructions for safely cleaning of your Fobbles
machine if output become noticeably decreased. The bubble mechanism should be rinsed ideally after ever use to minimize residue build
up. Typical service intervals for the fog heater core are every 40 hrs. of machine use. High quality fluid is recommended by the manufacturer
to lengthen the amount of time between periods of maintenance as described below.
Tools: Clean lint free cloth, coffee filter or similar fine mesh filter cloth, several plastic or glass containers (do not use metal), distilled water
and Froggys Fog fluid.
The recommended cleaning procedures are as follows.
General Maintenance
1.
Unplug the product from power.
2.
Remove dust from air vents with air compressor, vacuum, or soft brush. Excessive dust, fluid residue and dirt will
degrade performance and cause overheating.
3.
Wipe machine body clean with clean lint free cloth.
4.
Store the machine in a cool, dry place when not in use. Avoid freezing temperatures, high heat above 120 degrees and
humid/damp locations which could cause control board electrical issues.
Fog System
1.
Remove the cap assembly from the fog fluid reservoir.
2.
Dip the fog fluid intake tube into a container with distilled water.
3.
Connect the product to power and allow it to warm up.
4.
Operate the machine on 100% fog for 10 minutes in a well ventilated area. fog will come out in the first moments,
followed by steam. Do not allow the pump to run dry.
5.
After 10 minutes of operation, swap the fog intake tube into a container of fresh fog fluid and briefly run the machine
for 2 additional minutes.
6.
The fog fluid in the internal plumbing of the machine acts as lubricant for the fog pump's plastic and rubber
components during storage.
7.
Turn off the machine and empty any residual fog fluid from the fog reservoir. The fluid may be filtered into a container
for reuse.
8.
Restore the hoses and caps. Store the unit for next use once the machine is cool to the touch.
Bubble System
1.
Remove the cap assembly from the bubble fluid reservoir.