Color Screen Weather Station User Manual
5.7.3 Temperature/Humidity Trend Arrows
The temperature (2°F/1°C) and humidity (3%) trend indicators update every 30 minutes. The
trend reflects changes over the past 3 hours. E.G.: At 3:00
—
compares to 12:00 data; at 3:30
—
compares to 12:30.
Temperature or Humidity
increased in past 3 hours
Temperature or Humidity did
not change in past 3 hours
Temperature or Humidity
decreased in past 3 hours
5.7.4 Pressure Tendency Arrows
The forecast trend indicators update every 30 minutes. The trend reflects changes in pressure (1
hPa) over the past 3 hours.E.G.: At 3:00
—
compares to 12:00 data; at 3:30
—
compares to 12:30.
Pressure is rising, weather
expected to improve
Pressure is unchanged
Pressure is falling, weather
expected to worsen
5.7.5 Restoring Lost Outdoor Temperature and Humidity Sensor
If the signal is lost between the remote sensor (or transmitter) and the display console (or the
receiver), to resynchronize, while in normal mode, Press and hold
SET
and
TEMP
button for 5
seconds, to register the outdoor transmitter.
Please wait several minutes for the remote sensor reports in. Do not touch any buttons until
synchronization is complete.
If the synchronization fails, reset the console by removing one battery from the display console,
wait 10 seconds, and reinsert the battery, as specified in the console set up part.
6.
Glossary of Terms
Term
Definition
Absolute Barometric
Pressure
Relative barometric pressure, corrected to sea-level. To compare
pressure conditions from one location to another, meteorologists
correct pressure to sea-level conditions. Because the air pressure
decreases as you rise in altitude, the sea-level corrected pressure
(the pressure your location would be at if located at sea-level) is
generally higher than your measured pressure.
Accuracy
Accuracy is defined as the ability of a measurement to match the
actual value of the quantity being measured.