/ / PM POWDER MIXER
/ / /
14
Fig.
9
Control
cabinet
3.6
Vibratory Motor (Optional)
The vibratory motor causes the funnel to vibrate and facilitates uniform powder flow to the
bottom of the funnel.
If the vibratory motor is activated, it will run in specified switching cycles or switch off.
No.
Element
Design
Function
Switch for shear pump
[S3]
Rocker switch with indicator
light
Used to switch voltage supply for
the shear pump frequency con-
verter on and off
Switch for FZ pump [S2] Rocker switch with indicator
light
Used to switch FZ pump on and off
Vibratory motor switch
"Vibrating" [S4]
Selector switch with set
positions or selector dial
Used to switch external vibrator on
and off
Fault indicator "Fault"
[L1]
Indicator light
Lights up when faults occur (see
"Faults")
Emergency stop button Latching palm button
Used to turn off the powder mixer
in an emergency
Main switch [S1]
Selector dial
Used to turn on powder mixer
Set point potentiome-
ter (optional)
Control dial
Used to adjust the set point for
shear pump speed
Graphics and control
terminal for frequency
converter (example)
Panel with LCD, buttons,
and controls
Used to control the frequency con-
verter or start the shear pump
Table 1
Control and display elements on control cabinet