/ / FP PUMP SERIES / / /
18
9.7
Shaft Seal Replacement
The shaft seal must be replaced if:
– Pumping medium or sealing or quenching liquid flows out of
the pump on the atmosphere side.
– Sealing liquid leaks into the pumping medium.
Procedure
1. Remove the pump head (see
2. Replace the mechanical seal, and mount the pump head (see
Chapter 9.10, "Pump Head Attachment," page 20
). Perform the
following tasks according to the given shaft seal:
►
Preassemble the seals on the shaft.
►
Preassemble the pump casing.
►
Mount the pump casing on the lantern.
►
Mount the mechanical seal.
►
Mount the impeller.
►
Screw on the pump cover.
9.8
Pump Head Removal
9.8.1
Preparation
1. Turn off the motor and prevent it from being able to be
turned on accidentally.
2. Close the valve in the discharge line.
3. Close the valve in the suction line.
4. Completely empty the pump.
9.8.2
Procedure
Fig. 26
Pump cover
1. Loosen the nuts
on the pump cover.
2. Remove the nuts, the washers, the pump cover
, and the
cover seal
.
Fig. 27
Impeller
3.
WARNING:
Risk of injury when stopping the impeller by
hand. Block the impeller
with a wooden wedge.
, and remove with the O-ring
.
4. Take the snap ring
, and the key
off of the shaft.
5. Only for pumps with double shaft seals: Remove the flushing
tubes for sealing or quenching liquid.
TIP: For large pump casings, there is an M 12 thread on the
top of the casing. An eyebolt can be screwed into the thread
for suspension of the pump head from a crane.
6. Pull the pump head with the pump-side shaft seal off of the
shaft as follows:
6a. Clamp connection variant
1. Loosen the clamp bolt.
2. Slightly spread the clamp connection with a wedge.
3. Pull the pump casing out of the clamp connection.
6b. Flange connection variant
1. Loosen the fastening screws on the flange and remove.
2. Remove the pump casing.
7. Take the shaft seal out of the pump casing.
9.9
Checking of the Clearances
The position of the impeller is determined by the position on
the shaft. The clearances are set through the position of the
pump casing with respect to that of the impeller.
Note: For clearances, refer to table 6-8.
Prerequisites
– Pump casing is connected firmly to the lantern.
– Pump cover has been removed.
– The impeller has been mounted and the impeller nut tight-
ened.
36
37
38
39
40
41
42
43
Содержание FP
Страница 1: ...Original Instructions Assembly Instructions Centrifugal Pump FP Series Pump Type Pump No ...
Страница 32: ... FP PUMP SERIES 32 940 Key 941 Woodruff key 950 spring Part Number Name ...
Страница 37: ...37 ...
Страница 38: ... FP PUMP SERIES 38 ...
Страница 39: ...39 ...