EXHAUST DIRECTION

All dryers shipped from the factory are set up for rear exhausting.
However, on electric dryers, exhausting can be to the right or
left side of the cabinet or the bottom of the dryer. On gas dryers,
exhausting can be to the right side of the cabinet or the bottom
of the dryer. Directional exhausting can be accomplished by
installing Exhaust Kit, P/N 131456800, available through your
parts distributor. Follow the instructions supplied with the kit.

EXHAUST DUCT LOCATING DIMENSIONS

GAS SUPPLY REQUIREMENTS

 Replace copper connecting pipe that is not

plastic-coated. Stainless steel or plastic-coated brass MUST
be used.

1. Installation 

MUST

 conform with local codes, or in the absence

of local codes, with the National Fuel Gas Code, ANSI Z223.1
(latest edition) or in Canada, the current CAN/CGA B149.

2. The gas supply line should be of 1/2 inch (1.27 cm) pipe.
3. If codes allow, flexible metal tubing may be used to connect

your dryer to the gas supply line. The tubing 

MUST

 be

constructed of stainless steel or plastic-coated brass.

4. The gas supply line 

MUST 

have an individual shutoff valve.

5. A 1/8 inch (0.32 cm) N.P.T. plugged tapping, accessible for

test gauge connection, 

MUST

 be installed immediately

upstream of the gas supply connection to the dryer.

6. The dryer 

MUST

 be disconnected from the gas supply piping

system during any pressure testing of the gas supply piping
system at test pressures in excess of 1/2 psig (3.45 kPa).

7. The dryer 

MUST

 be isolated from the gas supply piping

system during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psig (3.45
kPa).

INSTALL MALE FITTINGS IN CORRECT DIRECTION

I

n installations where the exhaust system is not described in the

charts, the following method must be used to determine if the
exhaust system is acceptable:
1.

Connect an inclined or digital manometer between the
dryer and the point the exhaust connects to the dryer.

2.

Set the dryer timer and temperature to air fluff (cool
down) and start the dryer.

3.

Read the measurement on the manometer.

4.

The system back pressure 

MUST NOT

 be higher than

0.75 inches of water column.  If the system back
pressure is less than 0.75 inches of water column, the
system is acceptable.  If the manometer reading is
higher than 0.75 inches of water column, the system is
too restrictive and the installation is unacceptable.

Although vertical orientation of the exhaust system is
acceptable, certain extenuating circumstances could affect the
performance of the dryer:

Only the rigid metal duct work should be used.

Venting vertical through a roof may expose the exhaust
system to down drafts causing an increase in vent
restriction.

Running the exhaust system through an uninsulated area
may cause condensation and faster accumulation of lint.

Compression or crimping of the exhaust system will cause
an increase in vent restriction.

The exhaust system should be inspected and cleaned a
minimum of 

every 18 months 

with normal usage.  The more

the dryer is used, the more often you should check the
exhaust system and vent hood for proper operation.

CORRECT

CORRECT

CORRECT

CORRECT

CORRECT

INCORRECT

INCORRECT

INCORRECT

INCORRECT

INCORRECT

0

60 ft.

(18.28  m)

     48 ft.(14.63 m)

1

52 ft.

(15.84  m)

     40 ft.(12.19 m)

2

44 ft.

(13.41  m)

     32 ft.  (9.75 m)

3

32 ft.

  (9.75 m)

     24 ft.  (7.31 m)

4

28 ft.

  (8.53 m)

    16 ft.   (4.87 m)

0

30 ft.

 (9.14 m)

     18 ft. (5.49 m)

1

22 ft.

 (6.71 m)

     14 ft. (4.27 m)

2

14 ft.

 (4.27 m)

     10 ft. (3.05 m)

3

          NOT RECOMMENDED

VENT HOOD TYPE

(Preferred)

MAXIMUM LENGTH

of 4” (10.2 cm) Dia. Flexible Metal Duct

Number

 of

90°

 Turns

4”

(10.2 cm)

Louvered

VENT HOOD TYPE

(Preferred)

Number

 of

90°

 Turns

MAXIMUM LENGTH

of 4” (10.2 cm) Dia. Rigid Metal Duct

4”

(10.2 cm)

Louvered

SAME AS OTHER SIDE

SAME AS OTHER SIDE

SAME AS OTHER SIDE

SAME AS OTHER SIDE

SAME AS OTHER SIDE

(9.5 cm)

(9.5 cm)

(9.5 cm)

(9.5 cm)

(9.5 cm)

4 3/8"

4 3/8"

4 3/8"

4 3/8"

4 3/8"

(11 cm)

(11 cm)

(11 cm)

(11 cm)

(11 cm)

5 7/8"

5 7/8"

5 7/8"

5 7/8"

5 7/8"

(15 cm)

(15 cm)

(15 cm)

(15 cm)

(15 cm)

13 1/2"

13 1/2"

13 1/2"

13 1/2"

13 1/2"
(34 cm)

(34 cm)

(34 cm)

(34 cm)

(34 cm)

3 3/4"

3 3/4"

3 3/4"

3 3/4"

3 3/4"

(9.5 cm)

(9.5 cm)

(9.5 cm)

(9.5 cm)

(9.5 cm)

3 3/4"

3 3/4"

3 3/4"

3 3/4"

3 3/4"

(9.5 cm)

(9.5 cm)

(9.5 cm)

(9.5 cm)

(9.5 cm)

(6.35 cm)

2½"

(6.35 cm)

2½"

Содержание P/N 134296400A (0404)

Страница 1: ...of Your Dryer 4 Mobile Home Installation 5 Rough In Dimensions 5 6 Unpacking 6 Reversing Door Swing 6 Electrical Installation 7 Grounding Requirements 7 Electrical Connections 3 wire 8 Electrical Connections 4 wire 8 Installation 9 Replacement Parts 9 Printed in U S A P N 134296400A 0404 Installation Instructions Gas Electric Dryer Before beginning installation carefully read these instructions Th...

Страница 2: ...contact with exhaust system The dryer MUST NOT be exhausted into a chimney a wall a ceiling or any concealed space of a building which can accumulate lint resulting in a fire hazard Exceeding the length of duct pipe or number of elbows allowed in the MAXIMUM LENGTH charts can cause an accumulation of lint in the exhaust system Plugging the system could create a fire hazard as well as increase dryi...

Страница 3: ...temperature to air fluff cool down and start the dryer 3 Read the measurement on the manometer 4 The system back pressure MUST NOT be higher than 0 75 inches of water column If the system back pressure is less than 0 75 inches of water column the system is acceptable If the manometer reading is higher than 0 75 inches of water column the system is too restrictive and the installation is unacceptab...

Страница 4: ... centimeters 3 inches 7 6 cm from bottom and top of door THIS DRYER MUST BE EXHAUSTED OUTDOORS 5 The following illustrations show minimum clearance dimensions for proper operation in a recess or closet installation 0 0 cm 0 0 cm 0 0 cm 0 0 cm 0 0 cm 0 0 cm 0 0 cm 0 0 cm 0 0 cm 0 0 cm UNDER COUNTER INST UNDER COUNTER INST UNDER COUNTER INST UNDER COUNTER INST UNDER COUNTER INSTALLA ALLA ALLA ALLA A...

Страница 5: ...OPTIONAL OPTIONAL OPTIONAL OPTIONAL OPTIONAL VENT KNOCKOUT VENT KNOCKOUT VENT KNOCKOUT VENT KNOCKOUT VENT KNOCKOUT 3 3 4 3 3 4 3 3 4 3 3 4 3 3 4 9 5 cm 9 5 cm 9 5 cm 9 5 cm 9 5 cm MOBILE HOME INSTALLATION 1 Dryer MUST be exhausted outside outdoors not beneath the mobile home using metal ducting that will not support combustion Metal ducting must be 4 inches 10 16 cm in diameter with no obstruction...

Страница 6: ...counter model clothes dryers the top panel may be removed for installation 2 Return the dryer to an upright position PACKING FOAM SHIPPING REMOVE 4 SCREWS ONE FROM EACH HINGEFIRST ROUGH IN DIMENSIONS ROUGH IN DIMENSIONS ROUGH IN DIMENSIONS ROUGH IN DIMENSIONS ROUGH IN DIMENSIONS TOP CONSOLE MODELS 68 6 cm 68 6 cm 68 6 cm 68 6 cm 68 6 cm SIDE VIEW SIDE VIEW SIDE VIEW SIDE VIEW SIDE VIEW OPTIONAL OP...

Страница 7: ...plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances If in doubt call a licensed electrician ALL GAS Dryers This dryer is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong fr...

Страница 8: ...UTRAL GROUND WIRE ELECTRICAL CONNECTIONS FOR 3 WIRE SYSTEM Non Canadian ELECTRIC Dryer 1 Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner 2 Install a U L approved strain relief into the power cord entry hole of the mounting bracket Finger tighten the nut only at this time 3 Thread a U L approved 30 amp p...

Страница 9: ...so see that nothing such as boxes clothing etc obstructs the flow of combustion and ventilation air 6 Run the dryer through a cycle check for proper operation NOTE On gas dryers before the burner will light it is necessary for the gas line to be bled of air If the burner does not light within 45 seconds the first time the dryer is turned on the safety switch will shut the burner off If this happen...

Отзывы: