36" Glass Canopy Island 
Ceiling-Mount Hood Specifications

Product Weight – 84 Lbs.

Island / Peninsula Installation

Ventilation system is preset to exhaust air outside. If outside ducting is
not possible, optional Duct-Free Kit (PN # RHDFP60GS) is available to
convert ventilation to allow air to recirculate inside. 

(Refer to Ducted

Option Specifications for outside ventilation.)

Sones Rating – 9.0

Voltage Rating – 120V / 60 Hz / 15 Amps

Connected Load (kW Rating) @ 120 Volts = 0.516 kW (For use on
adequately wired 120V, dedicated circuit having 2-wire service with a
separate ground wire. Appliance must be grounded for safe operation.)

Amps @ 120 Volts = 4.16 Amps

Always consult local and national electric codes. Check local 
building codes for installation requirements, as they may vary per locale.

Minimum installation height allowed from bottom of hood to cooking
surface is 24" - 30" for electric and 30" for gas. 

(NOT more than 36"

recommended.)

To prepare mounting surface, adequate structure and support must be
provided, capable of supporting 150 lbs.

Ducted Option Specifications

For outside ventilation.

Exhaust Duct Required – 8" round

For most efficient airflow exhaust, use a straight run or as few elbows 
as possible.

Use metallic flex ducting only to connect rigid duct directly to transitions

(if allowed by code)

.

Thermal breaks such as short section of nonmetallic duct, should 
be used in areas of extreme cold.

Cold weather installations should have additional backdraft damper
installed.

Refer to installation instructions on web for detailed exhaust duct
preparation and converting vent blower system for recirculating inside.

Pre-Installation Calculations

Select hood preference height (P) that is comfortable for user 

(24" - 30" minimum allowed, NOT more than 36" recommended).

Calculate hood height (H) for installation (H = K-C-P).

Confirm that (H) is within minimum to maximum range for hood. 
If not, adjust installation.

Calculate chimney structure height (S). Use formulas, check 
dimensions of hood. Save calculation for use later in installation.

Note: For planning purposes only. Refer to Product Installation Guide 

on the web at electroluxappliances.com for detailed instructions.

Optional Accessories

Charcoal Filter – (PN # RHCFW60GS).

Duct-Free Kit (Single Pack) – (PN # RHDFP60GS). 

Top

Controls

Wiring box

Air outlet -
7

7

/

8

" diam.

Dimensions
from base of
hood to ceiling,
and include
clearance
required for
installation.

35

 7

/

8

"

25

 3

/

16

"

2

 11

/

16

"

12

 1

/

8

"

13

 3

/

16

"

 35"
min.

 57"

max.

 28"

 ( min.

height

 with one

 cover)

K = Kitchen height
C = Counter height
P = Preferred height

of hood bottom
above counter
(24"- 30"
allowed, NOT
more than 36"
recommended)

A = Canopy height
H = Hood height for

installation

H = K-C-P
S = Chimney

structure height
for installation

S = H-A

PRE-INSTALLATION CALCULATIONS

S H

A

K

P

C

Counter Height

36" standard