background image

4

Read all instructions before using this air conditioner

For Your Safety

Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance. Read product labels for
flammability and other warnings.

Prevent Accidents

Be sure the electrical service is adequate for the model you have chosen.
This information can be found on the serial plate, which is located either on
the side of the cabinet or behind the grille.
If the air conditioner is to be installed in a window, you will probably want to
clean both sides of the glass first. If the window is a triple-track type with a
screen panel included, remove the screen completely before installation.
Be sure the air conditioner has been securely and correctly installed
according to the separate installation instructions provided with this
manual. Save this manual and the installation instructions for possible
future use in removing or reinstalling this unit.
When handling the air conditioner , be careful to avoid cuts from sharp
metal fins on front and rear coils.

To reduce the risk of fire, electrical shock, or injury to persons when using
your air conditioner, follow basic precautions, including the following:

Electrical Information

Be sure the air conditioner is properly grounded. To minimize shock and fire
hazards, proper grounding is important. The power cord is equipped with a
three-prong grounding plug for protection against shock hazards.
Your air conditioner

be used in a properly grounded wall receptacle. If

the wall receptacle you intend to use is not adequately grounded or
protected by a time delay fuse or circuit breaker, have a qualified electrician
install the proper receptacle.
Do not run air conditioner with outside protective cover in place. This could
result in mechanical damage within the air conditioner.

must

Do not use an extension cord or an adapter plug.

The complete electrical rating of your new room air conditioner is stated on
the serial plate. Refer to the rating when checking the electrical requirements.

Avoid fire hazard or

electric shock. Do not use an
extension cord or an adaptor plug.
Do not remove any prong from the
power cord.

The power supply cord

with this air conditioner contains a
current detection device designed
to reduce the risk of fire.
Please refer to the section
“Operation of Current Device” for
details.
In the event that the power supply
cord is damaged, it cannot be
repaired it must be replaced with a
cord from the Product
Manufacturer.

Grounding type
wall receptacle

Do not, under
Any circumstances,
cut, remove,
or bypass the
grounding prong

Power supply cord with
3-pr

grounding plug

and current detection
device

ong

READ THIS SECTION BEFORE ATTEMPTING TO OPERATE AIR CONDITIONER.

Operation of Current
Device

The power supply cord contains a current device that senses damage to the power

cord. To test your power supply cord do the following:

Plug in the Air Conditioner.

2. The power supply cord will have TWO buttons on the plug head. Press the TEST

button. You will notice a click as the RESET button pops out.

3. Press the RESET button. Again you will notice a click as the button engages.

4. The power supply cord is now supplying electricity to the unit.

Do not use this device to turn the unit on or off.

Always make sure the RESET button is pushed in for correct operation.

The power supply cord must be replaced if it fails to reset when either the TEST

button is pushed, or it cannot be reset. A new one can be obtained from the

product manufacturer.

If power supply cord is damaged, it CANNOT be repaired. It MUST be replaced

by one obtained from the product manufacturer.

1.

NOTES:

?
?
?

?

Plug in &
press RESET

NOTE: Some plugs have
buttons on the side

Important Safety
Instructions

Содержание HEAVY DUTY AIR CONDITIONER

Страница 1: ...OW READ AND SAVE THESE INSTRUCTIONS MULTI STEP SPEED ELECTRONIC CONTROLS USE CARE MANUAL HEAVY DUTY AIR CONDITIONER P N 309000855 03 ...

Страница 2: ...nder this warranty must be obtained by following these steps in order 1 Contact Frigidaire Consumer Services or an authorized Frigidaire servicer 2 If there is a question as to where to obtain service contact our Consumer Relations Department at Frigidaire Company P O Box 212378 Augusta GA 30917 800 444 4944 ROOM AIR CONDITIONER WARRANTY Your product is protected by this warranty Your appliance is...

Страница 3: ... i f i c o p e r a t i n g instructions for your model Use the r o o m a i r c o n d i t i o n e r o n l y a s instructed in this Owner s Guide These instructions are not meant to cover every possible condition and situation that may occur Common sense and caution must be practiced when installing operating and maintaining any appliance Normal Sounds High Pitched Chatter Today s high efficient com...

Страница 4: ...This could result in mechanical damage within the air conditioner must Do not use an extension cord or an adapter plug The complete electrical rating of your new room air conditioner is stated on the serial plate Refer to the rating when checking the electrical requirements Avoid fire hazard or electric shock Do not use an extension cord or an adaptor plug Do not remove any prong from the power co...

Страница 5: ...DJUSTS TEMP TIMES SETS MODES AUTO TEMP REMOTE CONTROL LIGHT SETS FAN SPEEDS REMOTE SENSING On some Batter Size AA WARRING Do not Mix Old And New Batteries Do Not Mix Alkaline Standard Carbon Zinc Or Rechargeable Nichel Cadmium Batteries TO TURN UNIT ON YOU WILL SEE DO THIS PRESS ON OFF BUTTON DO THIS PRESS ON OFF BUTTON DO THIS PRESS TO RAISE PRESS TO LOWER TO CHANGE TEMERATURE SETTING YOU WILL SE...

Страница 6: ...ESS AUTO TEMP Note The fan speed will begin in HI then adjust to MED and LO as the room temperature conditions indicates For example in cooling if the room doesn t get too warm it will stay at LO If the room temperature rises quickly such as a door being opened it will automatically go to HI speed The fan speeds will adjust back to LO as the room returns to the original set temperature TO OPERATE ...

Страница 7: ...ck on YOU WILL SEE TIMER DELAY START STOP FEATURE YOU WILL SEE HOW MUCH TIME IS CHOSEN FIRST DO THIS PRESS TIMER BUTTON Note 1 For Delay Stop the unit must be in the ON position Note 2 For Delay Start the unit must be in the OFF position First PRESS TIME BUTTON Then To adjust timer setting tap or hold the UP arrow or DOWN arrow v to change the delay time by 5 hour increments up to 10 hours then by...

Страница 8: ...minder to clean the Air Filter See Care and Cleaning for more efficient operation and cooling The LED light will illuminate after 250 hours of operation To reset after cleaning the filter press the Clean Filter button and the light will go off CLEAN AIR FEATURE on some models YOU WILL SEE LIGHT ON Note When the feature is ON the ion generator is energized and will help to remove pollen and impurit...

Страница 9: ...ontrol will pulse to indicate it received the signal The LIGHT on the remote control will pulse each time it sends a signal It will continue to send this signal until the feature is deactivated by pressing the remote sensing stop button If the unit does not receive the remote sensing signal during any 3 minute interval the unit will keep to indicate the remote sensing mode has ended The display on...

Страница 10: ...The control will maintain any set temperature within 2 F between 60 F and 90 F degrees The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other press and hold the Up and Down Temperature Selection Pads at the same time for 3 seconds º º º Fresh Air Vent Control The Fresh Air Vent allows the air conditioner to 1 Recalculate inside ai...

Страница 11: ...ore wiping around the controls Excess water in or around the controls may cause damage to the air conditioner Plug in air conditioner The capacity of the room air conditioner must fit the room size for efficient and satisfactory operation Install the room air conditioner on the shady side of your home A window that faces north is best because it is shaded most of the day Close the fireplace damper...

Страница 12: ...rature is set too Low for night time cooling To defrost the coil set to FAN ONLY Mode Then set Temperature to a Higher number Dirty air filter air restricted Clean air filter Refer to Care and Cleaning section Temperature is set too High Set temperature to a Lower number Air directional louvers positioned improperly Position louvers for better air distribution Front of unit is blocked by drapes bl...