3
Error code chart
Error code
Fault condition
Check
E11
Fill time too long.
Refer to test (1).
E13
Water leak in tub or air leak in air bell.
Refer to test (2).
E14
Reed switch.
Refer to test (3).
E21
Water not pumping out fast enough.
Refer to test (4).
E23
Drain pump relay on control board failed.
Replace control board.
E24
Drain pump relay on control board failed.
Replace control board.
E31
Better models. Pressure sensor not communicating
Refer to test (5).
with control board.
E35
Better models. Pressure sensor indicates water overfill.
Refer to test (6).
E41
Control board thinks the door switch is open.
Refer to test (7).
E42
Door remains locked after cycle is completed.
Refer to test (8).
E43
Control board problem.
Replace the control board.
E44
Control board problem.
Replace the control board.
E45
Control board problem.
Replace the control board.
E46
Control board problem.
Replace the control board.
E47
Board thinks the door PTC circuit is open in spin.
Refer to test (9)
E48
Board thinks the door PTC circuit is closed.
Refer to test (9)
E52
Bad signal from tacho generator.
Refer to test (10)
E55
Motor overheating.
Refer to test (11)
E56
High motor current.
Refer to test (11)
E57
High current on inverter.
Refer to test (11)
E58
High current on motor phase.
Refer to test (11)
E59
No tacho signal for 3 seconds.
Refer to test (12)
E5A
High temperature on heat sink.
Replace the speed control
board.
E5B
High temperature on heat sink.
Replace the speed control
board.
E5C
High temperature on heat sink.
Replace the speed control
board.
E5D
Communication problem.
Refer to test (13)
E5E
Communication problem.
Refer to test (13)
E5F
Communication problem.
Refer to test (13)
E67
Input voltage on microprocessor incorrect.
Replace the control board.
E75
Better models only. Water temperature sensor circuit.
Refer to test (14)
E76
Better model only. NTC temperature for the cold water
Hot and cold water hoses
valve over the limits.
switched.
E95
Communication error.
Replace the control board.
EB1
Incoming power frequency out of limits.
Refer to test (15)
EB2
Incoming line voltage above 130 VAC.
Check voltage at the outlet. If
below 130 VAC, replace the
control board.
EB3
Incoming line voltage below 90 VAC.
Check voltage at the outlet. If
above 90 VAC, replace the
control board.
EF1
Clogged drain pump.
Unclog the drain pump.
EF2
To much soap.
Advise customer to reduce
the amount of soap they are
using.