ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
Figure 2 – COUNTERTOP CUTOUT OPENING
CAUTION
To eliminate the risk of burns or
fire by reaching over heated surfaces, cabinet
storage space located above the cooktop
should be avoided. If cabinet storage is
provided, risk can be reduced by installing a
range hood that projects horizontally a
minimum of 5" (12.7 cm) beyond the bottom
of the cabinets.
Letters on this figure refer to chart on front page except for
J & K
.
H
G
F
A
Overhead Cabinet Should Not Exceed a
Maximum Depth of 13" (33 cm)
30" (76.2 cm) Min.
Clearance Between the
Top of the Cooking
Platform and the Bottom
of an Unprotected Wood
or Metal Cabinet
24" (61 cm) Min. when
Bottom of Wood or
Metal Cabinet is
Protected by Not Less
Than 1/8" Flame
Retardant Millboard
Covered With Not Less
Than No. 28 MGS Sheet
Steel, 0.015" (0.4 mm)
Stainless Steel, 0.024"
(0.6 mm) Aluminum or
0.020" (0.5 mm)
Copper
2 1/2" (6.4 cm) Min. From Edge
of Cutout to Front Edge of
Countertop
Approximate Location
of Junction Box
18"
(45.7 cm)
It is not recommended to use
drawer underneath cooktop. Empty
space is needed for installation
purpose.
J
Min. From Edge of
Cooktop to Nearest
Combustible Wall
(Either Side of Unit).
12"
(30.5 cm)
10"
( 25.4 cm)
Min.
K
Min. Recommended
Distance Between Rear
Edge of Cutout and
Nearest Combustible
Surface Above
Countertop
24"
(61 cm)
M O D E L
J
K
30" Ceramic Glass
7½" (19.1 cm)
2" (5.1 cm)
36" Ceramic Glass
7½" (19.1 cm)
2" (5.1 cm)